Improved underwater Helmholtz resonator with an open cavity for sample volume estimation

COMPUTERS AND ELECTRONICS IN AGRICULTURE
  • Stephen N. Njane
  • ,
  • Yoshiaki Shinohara
  • ,
  • Naoshi Kondo
  • ,
  • Yuichi Ogawa
  • ,
  • Tetsuhito Suzuki
  • ,
  • Takahisa Nishizu

147
開始ページ
18
終了ページ
26
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.compag.2018.02.015
出版者・発行元
ELSEVIER SCI LTD

Helmholtz resonators with an opening on the side of the cavity have the potential to improve the limitations of closed cavity resonators as a practical means for determining sample volume underwater. When inserting samples into a closed cavity resonator, a door must be opened, the samples inserted and the door once more closed before commencing measurement. By incorporating an additional opening in the cavity, it could act as east access inlet for samples, as well as an entrance for live aquatic samples in the future. However, the characteristics of such an open cavity resonator are unknown, as is the mechanism for generating resonance in such a resonator. This acts as a barrier to the design and optimize these resonators. To overcome these issues, we first characterized the relationship between flow velocity and the region where Helmholtz resonance is generated. From this, we determined the optimal flow velocity to generate Helmholtz resonance in the cavity, taking into account the energy required to generate the signal, as well as avoiding unstable resonance generation regions. Our results demonstrate that the flow characteristics of an open cavity resonator are more stable with less jumps in frequency, than a closed cavity resonator. Moreover, for design optimization, we determined the cavity to sample volume ratio that gives the most sensitive resonance results. To do this, we used empirical equations to analyze the ratio of cavity volume to sample volume and demonstrated that a high cavity to sample volume ratio is preferable for a less dense sample (compared to water), while a lower cavity to sample volume ratio is desirable for a denser sample. In addition, this was experimentally validated using model samples that were either less dense or denser than water. The linear regression model for denser samples accounted for R-squared (R-2) of 99.7% and 99.5% of the variance of the actual sample volume in the open and closed cavity resonators, respectively. However, for less dense samples, the model accounted for R-squared (R-2) of 97.5% and 99.3% in the open cavity and closed cavity resonators, respectively. These results demonstrate that precise and non-invasive sample volume estimation is possible with an open cavity resonator, which can also be used as inlet in the future for aquatic sample insertion and volume estimation.

リンク情報
DOI
https://doi.org/10.1016/j.compag.2018.02.015
DBLP
https://dblp.uni-trier.de/rec/journals/cea/NjaneSKOSN18
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000428828200004&DestApp=WOS_CPL
URL
http://dblp.uni-trier.de/db/journals/cea/cea147.html#journals/cea/NjaneSKOSN18
ID情報
  • DOI : 10.1016/j.compag.2018.02.015
  • ISSN : 0168-1699
  • eISSN : 1872-7107
  • DBLP ID : journals/cea/NjaneSKOSN18
  • Web of Science ID : WOS:000428828200004

エクスポート
BibTeX RIS