2015年6月
Count-loss effect in subcriticality measurement by pulsed neutron source method, (II) proposal for utilization of neutron detection system operated in current mode
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY
- ,
- 巻
- 52
- 号
- 6
- 開始ページ
- 801
- 終了ページ
- 810
- 記述言語
- 英語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.1080/00223131.2014.978828
- 出版者・発行元
- TAYLOR & FRANCIS LTD
It was pointed out in the previous paper that the neutron decay constant determined by the pulsed neutron source method that employs the neutron detection system operated in the pulse mode is expected to be biased owing to the count-loss effect even when the intensity of pulsed neutron source is not high. To avoid this difficulty, by paying attention to the current mode that is inherently free from the count-loss process, the pulsed neutron source method with neutron detection system operated in the current mode was proposed. Using this method, not only the neutron decay constant but also the absolute value of subcriticality are obtained when a proper time constant of neutron detection system is selected.