2022年8月
Extraction of patient-specific boundary conditions from 4D-DSA and their influence on CFD simulations of cerebral aneurysms.
Computer methods in biomechanics and biomedical engineering
- 巻
- 25
- 号
- 11
- 開始ページ
- 1222
- 終了ページ
- 1234
- 記述言語
- 英語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.1080/10255842.2021.2005035
We developed a new technique for extracting patient-specific inflow conditions, such as the pulse cycle duration and blood flow velocity, from four-dimensional digital subtraction angiography images and experimentally examined its validity. The maximum error between the values extracted by the technique and measured values was 14.3%. We performed blood flow simulations and calculated representative haemodynamic parameters. The maximum differences between the parameters obtained using general and patient-specific inflow conditions were approximately 400%, 150%, and 50% for the velocity, normalised wall shear stress, and pressure loss coefficient, respectively. These results indicate that patient-specific conditions are critical for accurately reproducing aneurysmal haemodynamics.
- リンク情報
- ID情報
-
- DOI : 10.1080/10255842.2021.2005035
- PubMed ID : 35195493