2017年11月
Varus femoral and tibial coronal alignments result in different kinematics and kinetics after total knee arthroplasty
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
- ,
- ,
- ,
- ,
- ,
- ,
- ,
- 巻
- 25
- 号
- 11
- 開始ページ
- 3459
- 終了ページ
- 3466
- 記述言語
- 英語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.1007/s00167-017-4570-2
- 出版者・発行元
- SPRINGER
Abnormal knee motion under various conditions has been described after total knee arthroplasty (TKA). However, differences in kinematics and kinetics of knees with varus femoral versus varus tibial alignment have not been evaluated. It was hypothesized that varus femoral and tibial alignments have the same impact on knee motion.
A musculoskeletal computer simulation was used. Femoral and tibial alignment in the coronal plane was each varied from neutral to 5A degrees of varus in 1A degrees increments. Lift-off, defined as an intercomponent distance of > 2 mm, and tibiofemoral contact forces were evaluated during gait up to 60A degrees of knee flexion. Knee kinematics and contact stresses were also examined during squat, with up to 130A degrees of knee flexion.
During gait, lift-off occurred readily with more than 3A degrees of varus tibial alignment and slight lateral joint laxity. In contrast, lift-off did not occur with varus femoral or tibial alignment of up to 5A degrees during squat. Peak medial contact forces with varus femoral alignment were approximately twice those observed with varus tibial alignment. The lowest points of the femoral condyles moved internally with varus femoral alignment, contrary to the kinematics with neutral or varus tibial alignment. On the other hand, there was femoral medial sliding and edge loading against the tibia in mid-flexion with varus tibial alignment.
Varus femoral alignment affects the non-physiological rotational movement of the tibiofemoral joint, whereas varus tibial alignment causes medial-lateral instability during mid-flexion. Varus femoral and tibial alignments might lead to post-TKA discomfort and unreliability.
A musculoskeletal computer simulation was used. Femoral and tibial alignment in the coronal plane was each varied from neutral to 5A degrees of varus in 1A degrees increments. Lift-off, defined as an intercomponent distance of > 2 mm, and tibiofemoral contact forces were evaluated during gait up to 60A degrees of knee flexion. Knee kinematics and contact stresses were also examined during squat, with up to 130A degrees of knee flexion.
During gait, lift-off occurred readily with more than 3A degrees of varus tibial alignment and slight lateral joint laxity. In contrast, lift-off did not occur with varus femoral or tibial alignment of up to 5A degrees during squat. Peak medial contact forces with varus femoral alignment were approximately twice those observed with varus tibial alignment. The lowest points of the femoral condyles moved internally with varus femoral alignment, contrary to the kinematics with neutral or varus tibial alignment. On the other hand, there was femoral medial sliding and edge loading against the tibia in mid-flexion with varus tibial alignment.
Varus femoral alignment affects the non-physiological rotational movement of the tibiofemoral joint, whereas varus tibial alignment causes medial-lateral instability during mid-flexion. Varus femoral and tibial alignments might lead to post-TKA discomfort and unreliability.
- リンク情報
- ID情報
-
- DOI : 10.1007/s00167-017-4570-2
- ISSN : 0942-2056
- eISSN : 1433-7347
- PubMed ID : 28484791
- Web of Science ID : WOS:000413249900018