2010
The image correction method for PLIF measurements of high-schmidt-number scalar transfer (Nonmetric corrections for temporospatial variation of laser intensity and time variation of fluorescence quantum yield)
Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
- ,
- ,
- ,
- Volume
- 76
- Number
- 770
- First page
- 1543
- Last page
- 1551
- Language
- Japanese
- Publishing type
- Research paper (scientific journal)
- DOI
- 10.1299/kikaib.76.770_1543
- Publisher
- Japan Society of Mechanical Engineers
In the conduct of planar laser induced fluorescence (PLIF) measurements of high-Sc-number scalar transfer, the following errors are included in all captured images. First, local excitation intensity of fluorescence is affected by the surrounding concentration field. Secondly, fluorescence quantum yield has time dependence. Thirdly, laser intensity has temporospatial distribution. In this paper, we propose a nonmetric image correction method to improve the accuracy in PLIF measurement, in which above-mentioned problems were completely removed. The method was applied to the PLIF measurement of high-Sc-number scalar transfer in grid-generated turbulence. The results show that turbulence statistics on concentration are properly estimated by using the present method.
- Link information
- ID information
-
- DOI : 10.1299/kikaib.76.770_1543
- ISSN : 0387-5016
- SCOPUS ID : 78651458370