MISC

2014年6月

Nine-month angiographic and two-year clinical follow-up of polymer-free sirolimus-eluting stent versus durable-polymer sirolimus-eluting stent for coronary artery disease: the Nano randomized trial

CHINESE MEDICAL JOURNAL
  • Zhang Yaojun
  • Chen Fang
  • Takashi Muramatsu
  • Xu Bo
  • Li Zhanquan
  • Ge Junbo
  • He Qing
  • Yang Zhijian
  • Li Shumei
  • Wang Lefeng
  • Wang Haichang
  • He Ben
  • Li Kang
  • Qi Guoxian
  • Li Tianchang
  • Zeng Hesong
  • Peng Jianjun
  • Jiang Tieming
  • Zeng Qiutang
  • Zhu Jianhua
  • Fu Guosheng
  • Christos V. Bourantas
  • Patrick W. Serruys
  • Huo Yong
  • 全て表示

127
11
開始ページ
2153
終了ページ
2158
記述言語
英語
掲載種別
DOI
10.3760/cma.j.issn.0366-6999.20133148
出版者・発行元
CHINESE MEDICAL ASSOC

Background First generation drug-eluting stents (DES) were associated with a high incidence of late stent thrombosis (ST), mainly due to delayed healing and re-endothelization by the durable polymer coating. This study sought to assess the safety and efficacy of the Nano polymer-free sirolimus-eluting stent (SES) in the treatment of patients with de novo coronary artery lesions.
Methods The Nano trial is the first randomized trial designed to compare the safety and efficacy of the Nano polymer-free SES and Partner durable-polymer SES (Lepu Medical Technology, Beijing, China) in the treatment of patients with de novo native coronary lesions. The primary endpoint was in-stent late lumen loss (LLL) at 9-month follow-up. The secondary endpoint was major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction or target lesion revascularization.
Results A total of 291 patients (Nano group: n=143, Partner group: n=148) were enrolled in this trial from 19 Chinese centers. The Nano polymer-free SES was non-inferior to the Partner durable-polymer DES at the primary endpoint of 9 months (P <0.001). The 9-month in-segment LLL of the polymer-free Nano SES was comparable to the Partner SES (0.34 +/- 0.42) mm vs. (0.30 +/- 0.48) mm, P=0.21). The incidence of MACE in the Nano group were 7.6% compared to the Partner group of 5.9% (P=0.75) at 2 years follow-up. The frequency of cardiac death and stent thrombosis was low for both Nano and Partner SES (0.8% vs. 0.7%, 0.8% vs. 1.5%, both P=1.00).
Conclusions In this multicenter randomized Nano trial, the Nano polymer-free SES showed similar safety and efficacy compared with the Partner SES in the treatment of patients with de novo coronary artery lesions. Trials in patients with complex lesions and longer term follow-up are necessary to confirm the clinical performance of this novel Nano polymer-free SES.

リンク情報
DOI
https://doi.org/10.3760/cma.j.issn.0366-6999.20133148
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000339034300030&DestApp=WOS_CPL
ID情報
  • DOI : 10.3760/cma.j.issn.0366-6999.20133148
  • ISSN : 0366-6999
  • Web of Science ID : WOS:000339034300030

エクスポート
BibTeX RIS