Optimization of loading ratio of ErN as regenerator of 4K-GM cryocooler

Journal of Physics: Conference Series
  • T. Nakagawa
  • ,
  • T. Miyauchi
  • ,
  • T. Shiraishi
  • ,
  • S. Seino
  • ,
  • T. A. Yamamoto
  • ,
  • Y. Fujimoto
  • ,
  • S. Masuyama

897
1
開始ページ
012008
終了ページ
記述言語
英語
掲載種別
研究論文(国際会議プロシーディングス)
DOI
10.1088/1742-6596/897/1/012008

High purity erbium nitride (ErN) spheres with the size range of 150-180 μm and 180-212 μm were prepared by nitriding Er metal spheres with low oxygen content. The initial regenerator material of HoCu on the cold end of the second regenerator column in 4K-GM cryocooler with nominal cooling power of 0.1 W at 4.2 K was replaced by ErN with different sizes. Higher cooling power was obtained when ErN of smaller size with lower oxygen content was used. We investigated the effect of partial replacement of HoCu by ErN in the cold end side of second stage regenerator column on cooling power of 4K-GM cryocoolers. When ErN were substituted for 20 % of HoCu , the cooling power at 4.2 K reached 0.318 W. This value was 1.36 times as high as that of the cooling power of the GM cryocooler with commercially available regenerator arrangement. Therefore, use of ErN regenerator materials leads to the energy-saving and downsizing of 4K-GM cryocoolers. 2 2 2

リンク情報
DOI
https://doi.org/10.1088/1742-6596/897/1/012008
Scopus
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85032449259&origin=inward 本文へのリンクあり
Scopus Citedby
https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85032449259&origin=inward
ID情報
  • DOI : 10.1088/1742-6596/897/1/012008
  • ISSN : 1742-6588
  • eISSN : 1742-6596
  • SCOPUS ID : 85032449259

エクスポート
BibTeX RIS