Volume Reduction Effect of Thinly Extended Core Structure for Transformer in Isolated DC-DC Converter

ICPE 2019 - ECCE Asia - 10th International Conference on Power Electronics - ECCE Asia
  • R. Murata
  • ,
  • T. Shirakawa
  • ,
  • K. Umetani
  • ,
  • E. Hiraki

開始ページ
2132
終了ページ
2138
記述言語
掲載種別
研究論文(国際会議プロシーディングス)

© 2019 The Korean Institute of Power Electronics (KIPE). The high-frequency transformers used for isolated DC-DC converters tend to have large volume compared with the other components. Therefore, increasing the power density of the transformer is indispensable for increasing the power density of the DC-DC converter. Reducing the dead space of the transformer is one of the effective solutions. It is well-known that the thinly extended core structure reduces the dead space around the transformer formed by the windings protruding to the outside of the core. However, it has not been clarified how much the thinly extended core structure affects the reducing power loss of the transformer. In this paper, the effect of introducing the thinly extended core structure into the transformer is quantified by the optimization of the convertible design parameters of the transformer with systematic round-robin calculation. The result revealed the volume reduction effect by the thinly extended core was greater than the simply dead space reduction effect.