Takamichi Takashima

J-GLOBAL         Last updated: Aug 6, 2019 at 13:41
 
Avatar
Name
Takamichi Takashima

Research Areas

 
 

Published Papers

 
Sessa S, Zecca M, Bartolomeo L, Takashima T, Fujimoto H, Takanishi A
Healthcare technology letters   2(2) 58-63   Apr 2015   [Refereed]
Takuya Otani,A. Iizuka,D. Takamoto,Hiromitsu Motohashi,Tatsuhiro Kishi,Przemyslaw Kryczka,Nobutsuna Endo,Array,Kenji Hashimoto,Takamichi Takashima,Hun-ok Lim,Atsuo Takanishi
2013 IEEE International Conference on Robotics and Automation, Karlsruhe, Germany, May 6-10, 2013   667-672   2013   [Refereed]
Kenji Hashimoto,Hiromitsu Motohashi,Takamichi Takashima,Hun-ok Lim,Atsuo Takanishi
2013 IEEE International Conference on Robotics and Automation, Karlsruhe, Germany, May 6-10, 2013   686-691   2013   [Refereed]
Kenji Hashimoto,Yuki Takezaki,Kentaro Hattori,Hideki Kondo,Takamichi Takashima,Hun-ok Lim,Atsuo Takanishi
2010 IEEE/RSJ International Conference on Intelligent Robots and Systems, October 18-22, 2010, Taipei, Taiwan   2206-2211   2010   [Refereed]
Development of New Biped Foot Mechanism Mimicking Human's Foot Arch Structure
Hashimoto Kenji, Takezaki Yuki, Hattori Kentaro, Kondo Hideki, Takashima Takamichi, Lim Hun-ok, Takanishi Atsuo
ROMANSY 18: ROBOT DESIGN, DYNAMICS AND CONTROL   (524) 249-+   2010   [Refereed]
MINE Yasuhiro, TAKASHIMA Takamichi, FUJIMOTO Hiroshi
Transactions of the Japan Society of Mechanical Engineers C   74(740) 884-889   Apr 2008
We have studied concerning the design technique of ankle-foot orthosis (AFO) that is used spastic hemiplegia of the stroke. We developed the equipment for measurement in order to measure the influence which it causes to spasticity gait. The ankle ...
MINE Yasuhiro, KOBAYASHI Yoshiyuki, TAKASHIMA Takamichi, FUJIMOTO Hiroshi
Transactions of the Japan Society of Mechanical Engineers C   72(722) 3280-3285   Oct 2006
We developed the SMO (Spastic Measurement orthosis) in order to measure the feature of spasticity by the paralysis of stroke. Because we focused on patients suffering from hemiplegics stroke in order to develop a design method of an AFO, which fit...
KOBAYASHI Yoshiyuki, MINE Yasuhiro, TAKASHIMA Takamichi, FUJIMOTO Hiroshi
Transactions of the Japan Society of Mechanical Engineers C   72(720) 2574-2579   Aug 2006
Tactile ground surface indicators installed on sidewalks help visually impaired people walk safely. However, these indicators could be an extra barrier for people who do not use those indicators. In previous study, we suggest that a functional leg...
Kakihana W, Akai M, Nakazawa K, Takashima T, Naito K, Torii S
Archives of physical medicine and rehabilitation   86(7) 1465-1471   Jul 2005   [Refereed]
Kobayashi Y, Takashima T, Hayashi M, Fujimoto H
IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society   13(1) 53-59   Mar 2005   [Refereed]
KAKIHANA Wataru, AKAI Masami, NAKAZAWA Kimitaka, YAMASAKI Nobuya, TAKASHIMA Takamichi, NAITO Kenji, TORII Suguru
運動療法と物理療法 = The Journal of physical medicine   15(1) 42-48   May 2004
Kakihana W, Akai M, Yamasaki N, Takashima T, Nakazawa K
American journal of physical medicine & rehabilitation   83(4) 273-278   Apr 2004   [Refereed]
TAKASHIMA Takamichi, FUJIMOTO Hiroshi, KAKIHANA Wataru, TAKANISHI Atsuo
Transactions of the Japan Society of Mechanical Engineers. Series C.   69(688) 3251-3256   Dec 2003
The purpose of this study is to investigate the functional displacement of human foot complex during gait cycle. The methodlogy was to present the mathematical foot model which was three joints rigid rink 3 D model, consists of taroclural joint (T...
KOBAYASHI Yoshiyuki, TAKASHIMA Takamichi, HAYASHI Mieko, FUJIMOTO Hiroshi
Transactions of the Japan Society of Mechanical Engineers. Series C.   69(681) 1274-1280   May 2003
TAKASHIMA Takamichi, FUJIMOTO Hiroshi, TAKANISHI Atsuo
Transactions of the Japan Society of Mechanical Engineers. Series C.   68(672) 2425-2430   Aug 2002
"Arch moment" of human foot complex is determined by model analysis using Newton-Euler inverse dynamics argorism. Human foot is arch shaped structure that is highly complex, composed of 28 bones, any ligaments and intrinsic/extrinsic musculotendon...

Misc

 
装具療法と手指運動機能の定量的評価を同時に行うダイナミックスプリント用計測デバイスの提案
徳井 亜加根, 新谷 康介, 高嶋 孝倫, 春原 るみ, 西村 正暁, 岡田 充弘
The Japanese Journal of Rehabilitation Medicine   55(秋季特別号) S399-S399   Oct 2018
NAITO Hisashi, TAKASHIMA Takamichi, MATSUMOTO Takeshi, TANAKA Masao
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2009(0)    2010
NAITO Hisashi, TAKASHIMA Takamichi, MATSUMOTO Takeshi, TANAKA Masao
The Proceedings of the JSME Symposium on Welfare Engineering   2009(0) 24-25   2009
This paper describes construction of forward dynamical simulation considering foot segment deformation behavior. Foot segments, mechanical interface between external environment and body, are modeled as finite element model and other body segments...
【医学と工学技術】 義肢装具士養成教育における工学技術の役割
高嶋 孝倫
日本義肢装具学会誌   22(4) 196-198   Oct 2006
各種プラスチック製短下肢装具 短下肢装具の総論とバイオメカニクス
高嶋 孝倫
リハビリテーション医学   39(Suppl.) S129-S129   Apr 2002
TAKASHIMA Takamichi, KOINUMA Takeshi, FUJIMOTO Hiroshi, TAKANISHI Atsuo
Transactions of the Japan Society of Mechanical Engineers. Series C.   67(663) 3513-3518   Nov 2001
Transformation of the medial arch angle of human foot was observed at sagittal plane during gait cycle by two methods : X ray television and Computer Aided Video Motion Analysis (VICON). Although the X-ray television has access to measurement of a...
下肢装具
飛松 好子, 高嶋 孝倫, 佐々木 一彦
リハビリテーション医学   38(6) 457-459   Jun 2001
JICA補装具製作技術集団研修コースフォローアップ報告(パート2) 帰国研修員をたずねて 彼らの抱える問題と研修のありかた
小池 雅俊, 高嶋 孝倫
日本義肢装具学会誌   15(2) 179-183   Feb 1999
JICA補装具製作技術集団研修コースフォローアップ報告 帰国研修員をたずねて 彼らの抱える問題と研修のありかた
小池 雅俊, 高嶋 孝倫
日本義肢装具学会誌   15(1) 76-79   Jan 1999