2019年7月
CUBIC FLOCKED ELECTRODE EMBEDDING AMPLIFIER CIRCUIT FOR SMART ECG TEXTILE APPLICATION
2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII)
- ,
- ,
- ,
- ,
- 担当区分
- 筆頭著者
- 開始ページ
- 2189
- 終了ページ
- 2192
- 記述言語
- 英語
- 掲載種別
- 研究論文(国際会議プロシーディングス)
- 出版者・発行元
- IEEE
In order to develop smart electrocardiogram (ECG) textile, we proposed a novel dry electrode structure. The dry electrode was dimethylpolysiloxane (PDMS) cube on which Ag-plated fiber was flocked by electrostatic flocking technology. Also, the ECG amplifier circuit was embedded inside the PDMS cube. The good contact pressure between dry electrode and skin is significant for ECG measuring using a dry electrode. The structure enabled stable contact pressure. Additionally, reduction of wiring noise was expected because ECG signal can be amplified near the dry electrode. Because electrical devices such as MEMS sensor, battery, MCU and RE -1C can also be embedded inside the cubic dry electrode using this electrode structure, development of highly functional and flexible vital signs monitoring device can be realized.
Web of Science ® の 関連論文(Related Records®)ビュー
- リンク情報