論文

査読有り
2007年

Pharmacokinetics of telithromycin using bronchoscopic microsampling after single and multiple oral doses

PULMONARY PHARMACOLOGY & THERAPEUTICS
  • Junko Kikuchi
  • ,
  • Koichi Yamazaki
  • ,
  • Eiki Kikuchi
  • ,
  • Akitoshi Ishizaka
  • ,
  • Masaharu Nishimura

20
5
開始ページ
549
終了ページ
555
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.pupt.2006.05.006
出版者・発行元
ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD

Objectives: Bronchoscopic microsampling (BMS) is a new technique for repeated sampling of bronchial epithelial lining fluid (ELF) to obtain the pharmacokinetic profile of drugs. We analyzed the time versus concentration profiles of telithromycin in bronchial ELF obtained by BMS and compared these finding to those in plasma and alveolar ELF obtained by bronchoalveolar lavage (BAL).
Methods: Bronchial ELF samples were obtained from five healthy Subjects using BMS probe at 0, 2, 3, 4, 6, 10 and 24 h after single or multiple oral doses of 600 mg of telithromycin. Alveolar ELF was also obtained by BAL 3 h after single or multiple oral doses of 600 mg of telithromycin.
Results: The areas under the concentration-time curve from 0 to 24h (AUC0-24) of telithromycin in plasma and bronchial ELF were 2.86 +/- 0.60 and 19.5 +/- 10.4 mg h/l after single treatment and 3.60 +/- 0.49 and 42.2 +/- 22.7 mg h/l after multiple treatments, respectively. Single and multiple oral doses of telithromycin produced significantly (p < 0.05) higher AUC0-24 in bronchial ELF compared to those in plasma. While concentrations in bronchial ELF obtained by BMS were significantly lower than those in alveolar ELF obtained by BAL, they tended to be higher than those in plasma after multiple administration. The telithromycin concentrations obtained by BMS method were very consistent in bronchial ELF at different bronchi at one time point and at the same bronchus at different time points.
Conclusions: Using the BMS technique, we could describe the pharmacokinetics of telithromycin in bronchial ELF. Furthermore, BMS was reasonably validated and reconfirmed to be a feasible and reliable method for measuring antimicrobial concentrations in bronchial ELF. (c) 2006 Elsevier Ltd. All rights reserved.

リンク情報
DOI
https://doi.org/10.1016/j.pupt.2006.05.006
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/17127087
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000248999800013&DestApp=WOS_CPL
ID情報
  • DOI : 10.1016/j.pupt.2006.05.006
  • ISSN : 1094-5539
  • PubMed ID : 17127087
  • Web of Science ID : WOS:000248999800013

エクスポート
BibTeX RIS