On-ground calibration of the Hitomi Hard X-ray Telescopes

Journal of Astronomical Telescopes, Instruments, and Systems
  • Hideyuki Mori
  • Takuya Miyazawa
  • Hisamitsu Awaki
  • Hironori Matsumoto
  • Yasunori Babazaki
  • Ayako Bandai
  • Tadatsugu Demoto
  • Akihiro Furuzawa
  • Yoshito Haba
  • Takayuki Hayashi
  • Ryo Iizuka
  • Kazunori Ishibashi
  • Manabu Ishida
  • Naoki Ishida
  • Masayuki Itoh
  • Toshihiro Iwase
  • Hiroyoshi Kato
  • Hiroaki Kobayashi
  • Tatsuro Kosaka
  • Hideyo Kunieda
  • Shou Kurashima
  • Daichi Kurihara
  • Yuuji Kuroda
  • Yoshitomo Maeda
  • Yoshifumi Meshino
  • Ikuyuki Mitsuishi
  • Yuusuke Miyata
  • Housei Nagano
  • Yoshiharu Namba
  • Yasushi Ogasaka
  • Keiji Ogi
  • Takashi Okajima
  • Shigetaka Saji
  • Fumiya Shimasaki
  • Takuro Sato
  • Toshiki Sato
  • Naotsugu Shima
  • Satoshi Sugita
  • Yoshio Suzuki
  • Kenji Tachibana
  • Sasagu Tachibana
  • Shun'Ya Takizawa
  • Keisuke Tamura
  • Yuzuru Tawara
  • Kazuki Tomikawa
  • Tatsuharu Torii
  • Kentaro Uesugi
  • Koujun Yamashita
  • Shigeo Yamauchi
  • Display all

Volume
4
Number
1
First page
011210-1
Last page
011210-22
Language
English
Publishing type
Research paper (scientific journal)
DOI
10.1117/1.JATIS.4.1.011210

© 2018 The Authors. We present x-ray characteristics of the Hard X-ray Telescopes (HXTs) on board the Hitomi (ASTRO-H) satellite. Measurements were conducted at the SPring-8 BL20B2 beamline and the ISAS/JAXA 27-m beamline. The angular resolution defined by a half-power diameter was 1.9′ (HXT-1) and 2.1′ (HXT-2) at 8 keV, 1.9′ at 30 keV, and 1.8′ at 50 keV. The effective area was found to be 620cm2 at 8 keV, 178cm2 at 30 keV, and 82cm2 at 50 keV per mirror module. Although the angular resolutions were slightly worse than the requirement (1.7′), the effective areas sufficiently exceeded the requirements of 150cm2 at 30 keV and 55cm2 at 50 keV. The off-axis measurements of the effective areas resulted in the field of view being 6.1′ at 50 keV, 7.7′ at 30 keV, and 9.7′ at 8 keV in diameter. We confirmed that the main component of the stray x-ray light was significantly reduced by mounting the precollimator as designed. Detailed analysis of the data revealed that the angular resolution was degraded mainly by figure errors of mirror foils, and the angular resolution is completely explained by the figure errors, positioning errors of the foils, and conical approximation of the foil shape. We found that the effective areas were ∼80% of the designed values below 40 keV, whereas they steeply decline above 40 keV and become only ∼50%. We investigated this abrupt decline and found that neither the error of the multilayer design nor the errors of the incident angles induced by the positioning errors of the foils can be the cause. The reflection profile of each foil pair from the defocused image strongly suggests that the figure errors of the foils probably bring about the reduction in the effective areas at higher energies.

Link information
DOI
https://doi.org/10.1117/1.JATIS.4.1.011210
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000429569000016&DestApp=WOS_CPL
Scopus
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85041208273&origin=inward
Scopus Citedby
https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85041208273&origin=inward
ID information
  • DOI : 10.1117/1.JATIS.4.1.011210
  • ISSN : 2329-4124
  • eISSN : 2329-4221
  • SCOPUS ID : 85041208273
  • Web of Science ID : WOS:000429569000016

Export
BibTeX RIS