論文

査読有り 本文へのリンクあり
2019年9月15日

Objective Assessment of the Utility of Chromoendoscopy with a Support Vector Machine

Journal of Gastrointestinal Cancer
  • Ryo Ogawa
  • Jun Nishikawa
  • Eizaburo Hideura
  • Atsushi Goto
  • Yurika Koto
  • Shunsuke Ito
  • Madoka Unno
  • Yuko Yamaoka
  • Ryo Kawasato
  • Shinichi Hashimoto
  • Takeshi Okamoto
  • Hiroyuki Ogihara
  • Yoshihiko Hamamoto
  • Isao Sakaida
  • 全て表示

50
3
開始ページ
386
終了ページ
391
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1007/s12029-018-0083-6
出版者・発行元
Humana Press Inc.

© 2018, The Author(s). Purpose: The utility of chromoendoscopy for early gastric cancer (GC) was determined by machine learning using data of color differences. Methods: Eighteen histopathologically confirmed early GC lesions were examined. We prepared images from white light endoscopy (WL), indigo carmine (Indigo), and acetic acid-indigo carmine chromoendoscopy (AIM). A border between cancerous and non-cancerous areas on endoscopic images was established from post-treatment pathological findings, and 2000 pixels with equivalent luminance values were randomly extracted from each image of cancerous and non-cancerous areas. Each pixel was represented as a three-dimensional vector with RGB values and defined as a sample. We evaluated the Mahalanobis distance using RGB values, indicative of color differences between cancerous and non-cancerous areas. We then conducted diagnosis test using a support vector machine (SVM) for each image. SVM was trained using the 100 training samples per class and determined which area each of 1900 test samples per class came from. Results: The means of the Mahalanobis distances for WL, Indigo, and AIM were 1.52, 1.32, and 2.53, respectively and there were no significant differences in the three modalities. Diagnosability per endoscopy technique was assessed using the F1 measure. The means of F1 measures for WL, Indigo, and AIM were 0.636, 0.618, and 0.687, respectively. AIM images were better than WL and Indigo images for the diagnosis of GC. Conclusion: Objective assessment by SVM found AIM to be suitable for diagnosis of early GC based on color differences.

リンク情報
DOI
https://doi.org/10.1007/s12029-018-0083-6
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/29504086
Scopus
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85042754912&origin=inward 本文へのリンクあり
Scopus Citedby
https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85042754912&origin=inward
ID情報
  • DOI : 10.1007/s12029-018-0083-6
  • ISSN : 1941-6628
  • eISSN : 1941-6636
  • PubMed ID : 29504086
  • SCOPUS ID : 85042754912

エクスポート
BibTeX RIS