論文

査読有り
2012年4月

Highly sensitive detection of neodymium ion in small amount of spent nuclear fuel samples using novel fluorescent macrocyclic hexadentate polyaminocarboxylate probe in capillary electrophoresis-laser-induced fluorescence detection

JOURNAL OF CHROMATOGRAPHY A
  • Shingo Saito
  • ,
  • Yoshiyuki Sato
  • ,
  • Tomoko Haraga
  • ,
  • Yuta Nakano
  • ,
  • Shiho Asai
  • ,
  • Yutaka Kameo
  • ,
  • Kuniaki Takahashi
  • ,
  • Masami Shibukawa

1232
開始ページ
152
終了ページ
157
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.chroma.2011.11.032
出版者・発行元
ELSEVIER SCIENCE BV

A rapid and high-sensitive detection method for the total concentration of Nd ion (total Nd) in a small amount of a spent nuclear fuel sample is urgently required since the precise quantification of total Nd ion makes it possible for burnup (degree of fuel consumption) to be determined. In this work, a capillary electrophoresis-laser-induced fluorescent detection method (CE-LIF) is proposed for the analysis of total Nd in a spent fuel sample solution, with the use of a newly synthesized metal fluorescent probe which has a fluorescein and a macrocylic hexadentate chelating group, FTC-ABNOTA, for lanthanide (Ln) ions. Ln ions were derivatized to form a strongly fluorescent complex with the probe to suppress the quenching of the ligand-centered emission. The detection of Ln complexes in the CE-LIF indicated that the interaction between Ln ions and the FTC-ABNOTA was strong enough not to dissociate during migration. The mutual separation among the Ln-FTC-ABNOTA complexes in CE-LIF was achieved by pH control providing a dynamic ternary complexation (DTC) with hydroxide ions. Using the DTC separation mode, a high resolution of Nd from other Ln ions with high resolution of 1.3-1.9 and a theoretical plate number of 68,000, and a very low detection limit of 22 pM (3.2 ppt, 0.11 attomole amount basis) were successfully obtained. A simulated spent fuel sample containing various metal ions was examined in this method with a good quantification result of 102.1% recovery obtained even with a large excess of U. (C) 2011 Elsevier B.V. All rights reserved.

リンク情報
DOI
https://doi.org/10.1016/j.chroma.2011.11.032
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000302423000021&DestApp=WOS_CPL
URL
https://www.sciencedirect.com/science/article/pii/S0021967311017171?via%3Dihub
ID情報
  • DOI : 10.1016/j.chroma.2011.11.032
  • ISSN : 0021-9673
  • Web of Science ID : WOS:000302423000021

エクスポート
BibTeX RIS