One-step micromolding of complex 3D microchambers for single-cell analysis

Lab on a Chip
  • Hiroaki Suzuki
  • ,
  • Kenta Mitsuno
  • ,
  • Katsuyuki Shiroguchi
  • ,
  • Mamiko Tsugane
  • ,
  • Taiji Okano
  • ,
  • Tetsuji Dohi
  • ,
  • Tomoaki Tsuji

17
4
開始ページ
647
終了ページ
652
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1039/c6lc01313a
出版者・発行元
Royal Society of Chemistry

Herein we examined the extent of replicability of the PDMS microchamber device transferred from the master mold with complex 3D structures fabricated via micro stereolithography. Due to the elastomeric properties of PDMS, the reversely tapered micromold, with the diameter ratio of ∼5 from the largest to the narrowest part, was precisely transferred without breaking. We obtained the mathematical model to estimate the stress exerted on the mold during the demolding process. Finally, we tested the applicability of this unusual microchamber for single-cell trapping and an enzyme assay.