2015年
Frost Damage of Roof Tiles: A Study on Moisture Boundary Conditions
6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015)
- ,
- ,
- 巻
- 78
- 号
- 開始ページ
- 2530
- 終了ページ
- 2535
- 記述言語
- 英語
- 掲載種別
- 研究論文(国際会議プロシーディングス)
- DOI
- 10.1016/j.egypro.2015.11.263
- 出版者・発行元
- ELSEVIER SCIENCE BV
Freeze-thaw cycles are the most serious cause of roof tile deterioration; thus, it is important to know the temperature and moisture distributions in tile materials for protection against frost damage. This study focused on moisture boundary conditions for air layers under the tile. Temperature and humidity were measured using model structures with different types of roof tiles. The results showed that the temperatures around the roof were strongly influenced by solar and longwave radiation, and the humidity in the air layer was close to the outdoor. The ventilation rate between the outdoor and the air layer was estimated by numerical modelling based on the measured results. (C) 2015 The Authors. Published by Elsevier Ltd.
- リンク情報
- ID情報
-
- DOI : 10.1016/j.egypro.2015.11.263
- ISSN : 1876-6102
- Web of Science ID : WOS:000370934402099