2016 年熊本地震により被災した庁舎の地震後継続使用性の考察
日本建築学会技術報告集
- ,
- ,
- ,
- ,
- 巻
- 24
- 号
- 57
- 開始ページ
- 673
- 終了ページ
- 678
- 記述言語
- 日本語
- 掲載種別
- DOI
- 10.3130/aijt.24.673, 10.3130/aijs.86.893_references_DOI_6x9JEU2pSwmpSMecTZgdKg70knM
- 出版者・発行元
- 日本建築学会
<p>A reinforced concrete building was damaged by the 2016 Kumamoto earthquake. Functional use of the building was not allowed after the earthquake. In this paper, post-earthquake damage evaluation and static non-linear pushover analysis were carried out for the building. In the result, superstructure of the building was classified as moderate damage, however, damage classification of the foundation was heavy due to pile head damage. Furthermore, post-earthquake functional use of the building was discussed.</p>