2005年9月
方杖ダンパーを用いた柱梁高力ボルト接合構造の実大骨組実験
日本建築学会構造系論文集
- ,
- ,
- ,
- ,
- 巻
- 70
- 号
- 595
- 開始ページ
- 109
- 終了ページ
- 116
- 記述言語
- 日本語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.3130/aijs.70.109_2
- 出版者・発行元
- 日本建築学会
This paper presents the results of an experimental verification on a full-scale three story 'weld-free' structure, which is proposed as an innovative steel frame adopting mechanical joints equipped with buckling-restrained type knee brace dampers for wide-flange moment frames. Major findings are as follows: (1) The weld-free structure exhibits stable hysteresis behavior under 0.04 radian drift angle in-plane, (2) The yield mechanism by plastification of dampers and column bases meet the target mechanism, (3) The structure collapses by overall buckling of dampers and lateral-torsional buckling of beams but the maximum drift angle attained 0.10 radian preserving sufficient lateral resistance.
- リンク情報
- ID情報
-
- DOI : 10.3130/aijs.70.109_2
- ISSN : 1340-4202
- CiNii Articles ID : 110004839796
- CiNii Books ID : AN10438559