論文

査読有り 国際誌
2017年

A study of computer-aided diagnosis for pulmonary nodule: comparison between classification accuracies using calculated image features and imaging findings annotated by radiologists.

Int. J. Comput. Assist. Radiol. Surg.
  • Masami Kawagishi
  • Bin Chen
  • Daisuke Furukawa
  • Hiroyuki Sekiguchi
  • Koji Sakai
  • Takeshi Kubo
  • Masahiro Yakami
  • Koji Fujimoto
  • Ryo Sakamoto
  • Yutaka Emoto
  • Gakuto Aoyama
  • Yoshio Iizuka
  • Keita Nakagomi
  • Hiroyuki Yamamoto
  • Kaori Togashi
  • 全て表示

12
5
開始ページ
767
終了ページ
776
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1007/s11548-017-1554-0

PURPOSE: In our previous study, we developed a computer-aided diagnosis (CADx) system using imaging findings annotated by radiologists. The system, however, requires radiologists to input many imaging findings. In order to reduce such an interaction of radiologists, we further developed a CADx system using derived imaging findings based on calculated image features, in which the system only requires few user operations. The purpose of this study is to check whether calculated image features (CFT) or derived imaging findings (DFD) can represent information in imaging findings annotated by radiologists (AFD). METHODS: We calculate 2282 image features and derive 39 imaging findings by using information on a nodule position and its type (solid or ground-glass). These image features are categorized into shape features, texture features and imaging findings-specific features. Each imaging finding is derived based on each corresponding classifier using random forest. To check whether CFT or DFD can represent information in AFD, under an assumption that the accuracies of classifiers are the same if information included in input is the same, we constructed classifiers by using various types of information (CTT, DFD and AFD) and compared accuracies on an inferred diagnosis of a nodule. We employ SVM with RBF kernel as classifier to infer a diagnosis name. RESULTS: Accuracies of classifiers using DFD, CFT, AFD and CFT [Formula: see text] AFD were 0.613, 0.577, 0.773 and 0.790, respectively. Concordance rates between DFD and AFD of shape findings, texture findings and surrounding findings were 0.644, 0.871 and 0.768, respectively. CONCLUSIONS: The results suggest that CFT and AFD are similar information and CFT represent only a portion of AFD. Particularly, CFT did not contain shape information in AFD. In order to decrease an interaction of radiologists, a development of a method which overcomes these problems is necessary.

リンク情報
DOI
https://doi.org/10.1007/s11548-017-1554-0
DBLP
https://dblp.uni-trier.de/rec/journals/cars/KawagishiCFSSKY17
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/28285338
URL
https://www.wikidata.org/entity/Q47933512
URL
https://dblp.uni-trier.de/db/journals/cars/cars12.html#KawagishiCFSSKY17
ID情報
  • DOI : 10.1007/s11548-017-1554-0
  • ISSN : 1861-6410
  • DBLP ID : journals/cars/KawagishiCFSSKY17
  • PubMed ID : 28285338

エクスポート
BibTeX RIS