論文

査読有り
2015年3月

Heel strike detection using split force-plate treadmill

GAIT & POSTURE
  • Hossein Rouhani
  • ,
  • Masaki O. Abe
  • ,
  • Kimitaka Nakazawa
  • ,
  • Milos R. Popovic
  • ,
  • Kei Masani

41
3
開始ページ
863
終了ページ
866
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.gaitpost.2015.02.021
出版者・発行元
ELSEVIER IRELAND LTD

A common source of error when detecting heel-strike moments utilizing split force-plate treadmills is unwillingly stepping on contra-lateral force-plate. In this study, we quantified this error when heel-strike was detected based on such erroneous data and compared three methods to investigate how well the heel-strikes and stride-intervals were detected with erroneous data. Eleven subjects walked on a split force-plate treadmill for more than 20 min. We used 20 N and 50% body-weight thresholds to detect the heel-strike moments (HS20N and HS50%, respectively). Besides, we used linear approximation to estimate the unaffected force profile from affected force-plate data, and subsequently to detect the heel-strike moments (HSest). We used heel-strike moments detected by a foot-switch as a reference to compare accuracy of HS20N, HS50% and HSest. HS20N and HSest detected heel-strike moments accurately for unaffected force-plate data (median(max) errors for all subjects: 9(23) and 9(37) ms) but HS50% showed significantly larger errors (52(74) ms). Unlike HS50% and HSest, HS20N was considerably affected by the affected force-plate data (23(68) ms). The error in stride-interval measurement was relatively small using any methods for unaffected force-plate data (3(7), 6(8), and 6(12) ms), while stride-interval errors were large for some subjects when using HS20N for affected data (6(175) ms).
We concluded that unwillingly stepping on contra-lateral force-plate occurred a few percent and up to 37.7% of all strides (median: 12.9%). Our proposed method (HSest) robustly showed small errors for heel-strike detection and stride-interval calculation consistently among subjects, while HS50% and HS20N showed large errors depending on subjects. (C) 2015 Elsevier B.V. All rights reserved.

リンク情報
DOI
https://doi.org/10.1016/j.gaitpost.2015.02.021
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/25800003
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000353209200023&DestApp=WOS_CPL
ID情報
  • DOI : 10.1016/j.gaitpost.2015.02.021
  • ISSN : 0966-6362
  • eISSN : 1879-2219
  • PubMed ID : 25800003
  • Web of Science ID : WOS:000353209200023

エクスポート
BibTeX RIS