A common source of error when detecting heel-strike moments utilizing split force-plate treadmills is unwillingly stepping on contra-lateral force-plate. In this study, we quantified this error when heel-strike was detected based on such erroneous data and compared three methods to investigate how well the heel-strikes and stride-intervals were detected with erroneous data. Eleven subjects walked on a split force-plate treadmill for more than 20 min. We used 20 N and 50% body-weight thresholds to detect the heel-strike moments (HS20N and HS50%, respectively). Besides, we used linear approximation to estimate the unaffected force profile from affected force-plate data, and subsequently to detect the heel-strike moments (HSest). We used heel-strike moments detected by a foot-switch as a reference to compare accuracy of HS20N, HS50% and HSest. HS20N and HSest detected heel-strike moments accurately for unaffected force-plate data (median(max) errors for all subjects: 9(23) and 9(37) ms) but HS50% showed significantly larger errors (52(74) ms). Unlike HS50% and HSest, HS20N was considerably affected by the affected force-plate data (23(68) ms). The error in stride-interval measurement was relatively small using any methods for unaffected force-plate data (3(7), 6(8), and 6(12) ms), while stride-interval errors were large for some subjects when using HS20N for affected data (6(175) ms).
We concluded that unwillingly stepping on contra-lateral force-plate occurred a few percent and up to 37.7% of all strides (median: 12.9%). Our proposed method (HSest) robustly showed small errors for heel-strike detection and stride-interval calculation consistently among subjects, while HS50% and HS20N showed large errors depending on subjects. (C) 2015 Elsevier B.V. All rights reserved.
We concluded that unwillingly stepping on contra-lateral force-plate occurred a few percent and up to 37.7% of all strides (median: 12.9%). Our proposed method (HSest) robustly showed small errors for heel-strike detection and stride-interval calculation consistently among subjects, while HS50% and HS20N showed large errors depending on subjects. (C) 2015 Elsevier B.V. All rights reserved.
- リンク情報
- ID情報
-
- DOI : 10.1016/j.gaitpost.2015.02.021
- ISSN : 0966-6362
- eISSN : 1879-2219
- PubMed ID : 25800003
- Web of Science ID : WOS:000353209200023