Inter-fractional variations in the dosimetric parameters of accelerated partial breast irradiation using a strut-adjusted volume implant

JOURNAL OF RADIATION RESEARCH
  • Kotaro Iijima
  • Hiroyuki Okamoto
  • Kana Takahashi
  • Ako Aikawa
  • Akihisa Wakita
  • Satoshi Nakamura
  • Shie Nishioka
  • Ken Harada
  • Ryoichi Notake
  • Akimoto Sugawara
  • Ryoichi Yoshimura
  • Etsuo Kunieda
  • Jun Itami
  • 全て表示

61
1
開始ページ
123
終了ページ
133
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1093/jrr/rrz061
出版者・発行元
OXFORD UNIV PRESS

The aim of the study was to evaluate inter-fractional dosimetric variations for high-dose rate breast brachytherapy using a strut-adjusted volume implant (SAVI). For the nine patients included, dosimetric constraints for treatment were as follows: for the planning target volume for evaluation (PTV_Eval), the volume receiving 90, 150 and 200% of the prescribed dose (V-90%,V-150%,V-200%) should be >90%, <= 50 cm(3) and <= 20 cm(3), respectively; the dose covering 1 cm(3) (D-1cc) of the organs at risk should be <= 110% of the prescribed dose; and the air volume should be <= 10% of PTV_Eval. Differences in V-90%,V-150%,V-200%, D-1cc and air volume ( and ) as inter-fractional dosimetric variations and SAVI displacements were measured with pretreatment and planning computed tomography (CT) images. Inter-fractional dosimetric variations were analyzed for correlations with the SAVI displacements. The patients were divided into two groups based on the distance of the SAVI from the surface skin to assess the relationship between the insertion position of the SAVI and dosimetric parameters. The median Delta V-90%,V-150%,V-200% for the PTV_Eval in all patients was -0.3%, 0.2 cm(3) and 0.2 cm(3), respectively. The median (range) Delta D-1cc for the chest wall and surface skin was -0.8% (-18.9 to 9.4%) and 0.3% (-7.6 to 5.3%), respectively. SAVI displacement did not correlate with inter-fractional dosimetric variations. In conclusion, the dose constraints were satisfied in most cases. However, there were inter-fractional dosimetric changes due to SAVI displacement.

リンク情報
DOI
https://doi.org/10.1093/jrr/rrz061
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/31665490
PubMed Central
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7022137
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000518544600014&DestApp=WOS_CPL
ID情報
  • DOI : 10.1093/jrr/rrz061
  • ISSN : 0449-3060
  • eISSN : 1349-9157
  • PubMed ID : 31665490
  • PubMed Central 記事ID : PMC7022137
  • Web of Science ID : WOS:000518544600014

エクスポート
BibTeX RIS