論文

2021年9月10日

Time-dependent Diffusion in Brain Abscesses Investigated with Oscillating-gradient Spin-echo.

Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine
  • Tomoko Maekawa
  • Masaaki Hori
  • Katsutoshi Murata
  • Thorsten Feiweier
  • Kouhei Kamiya
  • Christina Andica
  • Akifumi Hagiwara
  • Shohei Fujita
  • Koji Kamagata
  • Akihiko Wada
  • Osamu Abe
  • Shigeki Aoki
  • 全て表示

21
4
開始ページ
525
終了ページ
530
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.2463/mrms.ici.2021-0083

Oscillating-gradient spin-echo sequences enable the measurement of diffusion weighting with a short diffusion time and can provide indications of internal structures. We report two cases of brain abscess in which the apparent diffusion coefficient (ADC) values appear higher at short diffusion times in comparison with those at long diffusion times. Diffusion time dependence of the ADC in brain abscesses suggests not only substrate viscosity but also restricted diffusion due to the structure within the lesions.

リンク情報
DOI
https://doi.org/10.2463/mrms.ici.2021-0083
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/34511577
PubMed Central
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618933
ID情報
  • DOI : 10.2463/mrms.ici.2021-0083
  • PubMed ID : 34511577
  • PubMed Central 記事ID : PMC9618933

エクスポート
BibTeX RIS