論文

査読有り 国際誌
2018年1月

Contrast-enhanced harmonic endoscopic ultrasonography for differential diagnosis of localized gallbladder lesions.

Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society
  • Ken Kamata
  • Mamoru Takenaka
  • Masayuki Kitano
  • Shunsuke Omoto
  • Takeshi Miyata
  • Kosuke Minaga
  • Kentaro Yamao
  • Hajime Imai
  • Tosiharu Sakurai
  • Naoshi Nishida
  • Hiroshi Kashida
  • Takaaki Chikugo
  • Yasutaka Chiba
  • Takuya Nakai
  • Yoshifumi Takeyama
  • Andrea Lisotti
  • Pietro Fusaroli
  • Masatoshi Kudo
  • 全て表示

30
1
開始ページ
98
終了ページ
106
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1111/den.12900
出版者・発行元
Blackwell Publishing

BACKGROUND AND AIM: Differential diagnosis of localized gallbladder lesions is challenging. The aim of the present study was to evaluate the utility of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) for diagnosis of localized gallbladder lesions. METHODS: One hundred and twenty-five patients with localized gallbladder lesions were evaluated by CH-EUS between March 2007 and February 2014. This was a single-center retrospective study. Utilities of fundamental B-mode EUS (FB-EUS) and CH-EUS in the differentiation of gallbladder lesions and sludge plug were initially compared. Thereafter, these two examinations were compared with respect to their accuracy in the diagnosis of malignant lesions. Five reviewers blinded to the clinicopathological results evaluated microcirculation patterns in the vascular and perfusion images. RESULTS: In the differentiation between gallbladder lesions and sludge plug, FB-EUS had a sensitivity, specificity, and accuracy of 82%, 100%, and 95%, respectively, whereas CH-EUS had a sensitivity, specificity, and accuracy of 100%, 99%, and 99%, respectively. FB-EUS-based diagnosis of carcinomas based on tumor size and/or shape had a sensitivity, specificity, and accuracy of 61-87%, 71-88%, and 74-86%, respectively. Additional information regarding irregular vessel patterns in the vascular image and/or heterogeneous enhancement in the perfusion image on CH-EUS increased the sensitivity, specificity, and accuracy for the diagnosis of carcinomas to 90%, 98%, and 96%, respectively. There was a significant difference between FB-EUS and CH-EUS in terms of carcinoma diagnosis. CONCLUSION: CH-EUS was useful for the evaluation of localized gallbladder lesions.

リンク情報
DOI
https://doi.org/10.1111/den.12900
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/28632914
ID情報
  • DOI : 10.1111/den.12900
  • ISSN : 1443-1661
  • ISSN : 0915-5635
  • PubMed ID : 28632914
  • SCOPUS ID : 85023777462

エクスポート
BibTeX RIS