2001年3月
新素材カセッテの表面材質の画質に与える影響について
日本放射線技術学会雑誌
- ,
- ,
- ,
- ,
- ,
- ,
- ,
- ,
- 巻
- 57
- 号
- 3
- 開始ページ
- 337
- 終了ページ
- 343
- 記述言語
- 日本語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.6009/jjrt.KJ00001357527
- 出版者・発行元
- 公益社団法人 日本放射線技術学会
This report describes a comparison of cassette front material in terms of its effect on radiographic imaging. We compared aluminum, carbon fiber, and a new material (Hylite) in terms of their absorption, scatter rate (lead-disc method), MTF, and subjective appearance, using an extremity phantom. For scatter rate and MTF, we also carried out analysis using Monte Carlo simulation. Results indicated that the cassette using the new material was intermediate between the aluminum panel and CFRP panel in terms of weight, absorption rate, and scatter rate. We also found that the new panel material showed a visual difference from the aluminum panel when a lower tube voltage and thinner object were assigned.
- リンク情報
- ID情報
-
- DOI : 10.6009/jjrt.KJ00001357527
- ISSN : 0369-4305
- J-Global ID : 200902151839281242
- CiNii Articles ID : 110003439435
- CiNii Books ID : AN00197784