MISC

2005年10月

Geothermal reservoir monitoring by continuous self-potential measurements, Mori geothermal field, Japan

GEOTHERMICS
  • K Yasukawa
  • ,
  • T Ishido
  • ,
  • Suzuki, I

34
5
開始ページ
551
終了ページ
567
記述言語
英語
掲載種別
DOI
10.1016/j.geothermics.2005.04.005
出版者・発行元
PERGAMON-ELSEVIER SCIENCE LTD

A self-potential (SP) monitoring study was conducted at the Mori geothermal field, Japan, to detect fluid flow changes in the reservoir caused by well operations. In 2000, eight observation points were deployed in and around the reservoir region for about 2.5 months, during which the production and reinjection wells were shut in and then re-opened. Since no reliable remote reference was available, the SP results were plotted in two ways: adopting an observation point in the target area as reference, and using the average value of all the observation points as a reference (called the "relative SP'' plot). Although changes in SP corresponding to well operations were detected in both plots, more reliable results were obtained with the relative SP plot. Based on numerical simulation of SP using a simplified model of the Mori reservoir, the observed changes are interpreted as being caused by reservoir pressure changes through electrokinetic coupling. (c) 2005 CNR. Published by Elsevier Ltd. All rights reserved.

リンク情報
DOI
https://doi.org/10.1016/j.geothermics.2005.04.005
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000232072700001&DestApp=WOS_CPL
ID情報
  • DOI : 10.1016/j.geothermics.2005.04.005
  • ISSN : 0375-6505
  • Web of Science ID : WOS:000232072700001

エクスポート
BibTeX RIS