2015年1月
当て板接着された突合せ鋼板のはく離強度の評価
鋼構造論文集
- ,
- ,
- ,
- ,
- 巻
- 22
- 号
- 86
- 開始ページ
- 86_1
- 終了ページ
- 86_11
- 記述言語
- 日本語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.11273/jssc.22.86_1
- 出版者・発行元
- 社団法人 日本鋼構造協会
Recently, bonding patch plate is used for rehabilitation of steel structures deteriorated with corrosion or fatigue cracks. The patch plate tends to decreases the stress intensity factor at crack tip and delay the crack propagation. However, debonding of patch plates could occur around the end of patch plates and at fatigue crack edges. To evaluate debonding of patch plates bonded to the cracked steel plate, axial loading tests for butted steel joint with bonded patch plates were conducted. Furthermore, the shear and normal stresses in adhesive layer were analyzed. The debonding strength of the joint was evaluated from a view of principal stress in adhesive layer.
- リンク情報
- ID情報
-
- DOI : 10.11273/jssc.22.86_1
- ISSN : 1880-9928
- CiNii Articles ID : 130005161702