MISC

査読有り
2008年

Forced convection heat transfer of subcooled liquid nitrogen in horizontal tube

AIP Conference Proceedings
  • H. Tatsumoto
  • ,
  • Y. Shirai
  • ,
  • K. Hata
  • ,
  • T. Kato
  • ,
  • M. Shiotsu

985
開始ページ
665
終了ページ
672
記述言語
英語
掲載種別
DOI
10.1063/1.2908652

The knowledge of forced convection heat transfer of liquid hydrogen is important for the cooling design of a HTS superconducting magnet and a cold neutron moderator material. An experimental apparatus that could obtain forced flow without a pump was developed. As a first step of the study, the forced flow heat transfer of subcooled liquid nitrogen in a horizontal tube, instead of liquid hydrogen, was measured for the pressures ranging from 0.3 to 2.5 MPa. The inlet temperature was varied from 78 K to around its saturation temperature. The flow velocities were varied from 0.1 to 7 m/s. The heat transfer coefficients in the non-boiling region and the departure from nucleate boiling (DNB) heat fluxes were higher for higher flow velocity and higher subcooling. The measured values of Nu/Pr0.4 in the non-boiling region were proportional to Reynolds number (Re) to the power of 0.8. With a decrease in Re, Nu/Pr0.4 approached a constant value corresponding to that in a pool of liquid nitrogen. The correlation of DNB heat flux was derived that can describe the experimental data within ±15% difference. © 2008 American Institute of Physics.

リンク情報
DOI
https://doi.org/10.1063/1.2908652
J-GLOBAL
https://jglobal.jst.go.jp/detail?JGLOBAL_ID=201002294867620806
Scopus
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=42449100712&origin=inward
Scopus Citedby
https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=42449100712&origin=inward
URL
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=42449100712&origin=inward
ID情報
  • DOI : 10.1063/1.2908652
  • ISSN : 0094-243X
  • eISSN : 1551-7616
  • J-Global ID : 201002294867620806
  • SCOPUS ID : 42449100712

エクスポート
BibTeX RIS