2014年
Forced convection heat transfer of saturated liquid hydrogen in vertically-mounted heated pipes
AIP Conference Proceedings
- ,
- ,
- ,
- ,
- ,
- ,
- 巻
- 1573
- 号
- 開始ページ
- 44
- 終了ページ
- 51
- 記述言語
- 英語
- 掲載種別
- 研究論文(国際会議プロシーディングス)
- DOI
- 10.1063/1.4860681
- 出版者・発行元
- AMER INST PHYSICS
Heat transfer from the inner side of vertically-mounted heated pipes to forced flow of saturated liquid hydrogen was measured with a quasi-steady increase of a heat generation rate for wide ranges of flow rate and saturated pressure. The tube heaters have lengths L of 100 mm and 167 mm with the diameter D of 4 mm and lengths of 150 mm and 250 mm with the diameter of 6 mm. The heat fluxes at departure from nucleate boiling (DNB) were higher for higher flow velocity, lower pressures and shorter L/D. The effect of L/D on the DNB heat flux was clarified. It is confirmed that our DNB correlation can describe the experimental data.
- リンク情報
-
- DOI
- https://doi.org/10.1063/1.4860681
- Web of Science
- https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000343409400006&DestApp=WOS_CPL
- Scopus
- https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85030688891&origin=inward
- Scopus Citedby
- https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85030688891&origin=inward
- ID情報
-
- DOI : 10.1063/1.4860681
- ISSN : 0094-243X
- eISSN : 1551-7616
- SCOPUS ID : 85030688891
- Web of Science ID : WOS:000343409400006