Rapid and highly sensitive analysis of benzodiazepines and tandospirone in human plasma by automated on-line column-switching UFLC-MS/MS

LEGAL MEDICINE
  • Xiao-Pen Lee
  • ,
  • Yukiko Shouji
  • ,
  • Takeshi Kumazawa
  • ,
  • Chika Hasegawa
  • ,
  • Masaya Fujishiro
  • ,
  • Junichi Sato
  • ,
  • Iwao Hasegawa
  • ,
  • Keizo Sato

24
開始ページ
36
終了ページ
55
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.legalmed.2016.11.005
出版者・発行元
ELSEVIER IRELAND LTD

A high-throughput method was developed for the detection of 31 benzodiazepine drugs and tandospirone in human plasma by on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry. Plasma samples (100 mu 1) spiked with the 32 drugs and oxazepam-d(5) (internal standard) were diluted with 300 mu 1 of 13.3 mM ammonium acetate/acetonitrile (33:67, v/v). After centrifugation and filtration, the clear supernatant was injected directly onto the extraction column (Oasis HLB cartridge column). The following procedure was fully automated. The analytes retained on the extraction column were eluted by backflushing of the extraction column and introduced into an analytical column (SUMIPAX ODS D-Swifter column, 30 mm x 3.0 mm i.d.; particle size 21.1m) by column switching. Quantification was performed by multiple reaction monitoring with positive-ion electrospray ionization. Distinct peaks appeared for each drug and the internal standard on each channel within 7 min, including the extraction time. All drugs spiked into plasma showed recoveries of 83-95%. The regression equations for the 32 drugs showed excellent linearities in the range of 50-2000 pg/ml of plasma and the limits of detection ranged from 20 to 50 pgiml. The lower and upper limits of quantitation were 50-100 ng/m1 and 2000 peril, respectively. Intra- and interday coefficients of variation for none of the drugs were greater than 13.6%. The accuracies of quantitation were 87-112%. The multiple reaction monitoring information dependent acquisition of enhanced product ions method enabled the quantification and confirmation of diazepam, triazolam, and lorazepam obtained from actual plasma. (C) 2016 Elsevier Ireland Ltd. All rights reserved.

リンク情報
DOI
https://doi.org/10.1016/j.legalmed.2016.11.005
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/28081789
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000393010700007&DestApp=WOS_CPL
ID情報
  • DOI : 10.1016/j.legalmed.2016.11.005
  • ISSN : 1344-6223
  • PubMed ID : 28081789
  • Web of Science ID : WOS:000393010700007

エクスポート
BibTeX RIS