MISC

1995年

A Study on the pulsation error of Area-Type Flowmeter -The Effect of the Taper Angle of the Meter Tube on the Pulsation Error-

TRANSACTION OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS
  • 金住 順二

31
4
開始ページ
529
終了ページ
531
DOI
10.9746/sicetr1965.31.529
出版者・発行元
The Society of Instrument and Control Engineers

The effect of the taper angle of the meter tube on the pulsation error of area-type flowmeter is examined theoretically. For some caces of the taper angle the pulsation errors are calculated on the basis of equation of motion taking into the factor of taper angle of meter tube. It is found that the pulsation error which are produced in the intermediate zone of pulsation frequency (0.2<λ<20) are influenced mainly by the taper angle of the meter tube.

リンク情報
DOI
https://doi.org/10.9746/sicetr1965.31.529
CiNii Articles
http://ci.nii.ac.jp/naid/130003970338
URL
https://jlc.jst.go.jp/DN/JALC/00032557527?from=CiNii
ID情報
  • DOI : 10.9746/sicetr1965.31.529
  • ISSN : 0453-4654
  • CiNii Articles ID : 130003970338