Scatter Correction with Combined Single-Scatter Simulation and Monte Carlo Simulation Scaling Improved the Visual Artifacts and Quantification in 3-Dimensional Brain PET/CT Imaging with O-15-Gas Inhalation

JOURNAL OF NUCLEAR MEDICINE
  • Keiichi Magota
  • Tohru Shiga
  • Yukari Asano
  • Daiki Shinyama
  • Jinghan Ye
  • Amy E. Perkins
  • Piotr J. Maniawski
  • Takuya Toyonaga
  • Kentaro Kobayashi
  • Kenji Hirata
  • Chietsugu Katoh
  • Naoya Hattori
  • Nagara Tamaki
  • 全て表示

58
12
開始ページ
2020
終了ページ
2025
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.2967/jnumed.117.193060
出版者・発行元
SOC NUCLEAR MEDICINE INC

In 3-dimensional PET/CT imaging of the brain with O-15-gas inhalation, high radioactivity in the face mask creates cold artifacts and affects the quantitative accuracy when scatter is corrected by conventional methods (e.g., single-scatter simulation [SSS] with tailfitting scaling [TFS-SSS]). Here we examined the validity of a newly developed scatter-correction method that combines SSS with a scaling factor calculated by Monte Carlo simulation (MCS-SSS). Methods: We performed phantom experiments and patient studies. In the phantom experiments, a plastic bottle simulating a face mask was attached to a cylindric phantom simulating the brain. The cylindric phantom was filled with F-18-FDG solution (3.8-7.0 kBq/mL). The bottle was filled with nonradioactive air or various levels of F-18-FDG (0-170 kBq/mL). Images were corrected either by TFS-SSS or MCS-SSS using the CT data of the bottle filled with nonradioactive air. We compared the image activity concentration in the cylindric phantom with the true activity concentration. We also performed 15O-gas brain PET based on the steady-state method on patients with cerebrovascular disease to obtain quantitative images of cerebral blood flow and oxygen metabolism. Results: In the phantom experiments, a cold artifact was observed immediately next to the bottle on TFS-SSS images, where the image activity concentrations in the cylindric phantom were underestimated by 18%, 36%, and 70% at the bottle radioactivity levels of 2.4, 5.1, and 9.7 kBq/mL, respectively. At higher bottle radioactivity, the image activity concentrations in the cylindric phantom were greater than 98% underestimated. For the MCS-SSS, in contrast, the error was within 5% at each bottle radioactivity level, although the image generated slight high-activity artifacts around the bottle when the bottle contained significantly high radioactivity. In the patient imaging with O-15(2) and (CO2)-O-15 inhalation, cold artifacts were observed on TFS-SSS images, whereas no artifacts were observed on any of the MCS-SSS images. Conclusion: MCS-SSS accurately corrected the scatters in O-15-gas brain PET when the 3-dimensional acquisition mode was used, preventing the generation of cold artifacts, which were observed immediately next to a face mask on TFS-SSS images. The MCS-SSS method will contribute to accurate quantitative assessments.

リンク情報
DOI
https://doi.org/10.2967/jnumed.117.193060
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000416804900035&DestApp=WOS_CPL
ID情報
  • DOI : 10.2967/jnumed.117.193060
  • ISSN : 0161-5505
  • eISSN : 1535-5667
  • Web of Science ID : WOS:000416804900035

エクスポート
BibTeX RIS