論文

査読有り
1996年12月

環境音・室温・照度の複合環境評価に関する基礎的考察 特異的評価と非特異的評価の関係

日本建築学会計画系論文集
  • 長野和雄
  • ,
  • 松原斎樹
  • ,
  • 藏澄美仁
  • ,
  • 合掌 顕
  • ,
  • 伊藤香苗
  • ,
  • 鳴海大典

61
490
開始ページ
55
終了ページ
61
記述言語
日本語
掲載種別
研究論文(学術雑誌)
DOI
10.3130/aija.61.55_3
出版者・発行元
社団法人日本建築学会

This study discussed the combined effect of sound, ambient temperature and illuminance on the evaluation of the environment in a room. Since there are many environmental factors in a room, the non-specific image of the combined environment was measured in this study. Subjects evaluated the combined environment of eight kinds of sounds, two levels of temperature (19, 24℃ (SET^*)) and two levels of illuminance (5,530(lx)) on seven-points bipolar scales of 23 adjectives by Semantic Differential Technique. Sutjects were 21 male students. The result of factor analysis was different from Izumi et al. (1983) which discussed the specific impression of sound. It was suggested that the difference between them is caused by the difference between non-specific and specific evaluation of sound. Since plural factors have significant effects on every evaluation, it was suggested that even in the case of the study on the specific evaluation, the other environmental factors should be recorded.

リンク情報
DOI
https://doi.org/10.3130/aija.61.55_3
CiNii Articles
http://ci.nii.ac.jp/naid/110004654508
CiNii Books
http://ci.nii.ac.jp/ncid/AN10438548
ID情報
  • DOI : 10.3130/aija.61.55_3
  • ISSN : 1340-4210
  • CiNii Articles ID : 110004654508
  • CiNii Books ID : AN10438548
  • identifiers.cinii_nr_id : 1000090322297

エクスポート
BibTeX RIS