2004年6月
Performances of a linear type magnetic flux pump for compensating a little decremented persistent current of HTS magnets
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
- ,
- ,
- ,
- 巻
- 14
- 号
- 2
- 開始ページ
- 1723
- 終了ページ
- 1726
- 記述言語
- 英語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.1109/TASC.2004.831054
- 出版者・発行元
- IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
This paper describes the characteristics of a linear type magnetic flux pump recently developed. The linear type flux pump has been fabricated to apply to compensate decremented persistent current of HTS applications such as NMR and MRI system. The linear type magnetic flux pump mainly consists of 3-phase AC armature coil, DC bias coil and superconducting Nb foil. In the preliminary experiment, the flux pump can charge the pumping-up current in the load coil of 1.3 mH during 1000 seconds under the DC bias current of 10 A and 3-phase AC of 8 A, 60 Hz. The magnitude of pumping current is 0.1 mA/s.
- リンク情報
- ID情報
-
- DOI : 10.1109/TASC.2004.831054
- ISSN : 1051-8223
- Web of Science ID : WOS:000223147500383