論文

2001年3月

DC reactor effect on bridge type superconducting fault current limiter during load increasing

IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
  • T Hoshino
  • ,
  • KM Salim
  • ,
  • M Nishikawa
  • ,
  • Muta, I
  • ,
  • T Nakamura

11
1
開始ページ
1944
終了ページ
1947
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1109/77.920232
出版者・発行元
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC

In high power application, the fault current limiter has been discussed for many years because of some limitations of conventional circuit breaker. Many types of fault current limiter have already been introduced in papers. In this work, a simple bridge type fault current limiter has been designed and constructed. The performances of the limiter have been tested successfully. In bridge type current limiter, DC reactor appears in the line when connected load is increasing. This causes voltage drop across the load terminal during load changing. The DC reactor effect of the current limiter has been studied. Some experimental results regarding reactor effect of the limiter have been considered and were compared with the results obtained from computer simulation.


リンク情報
DOI
https://doi.org/10.1109/77.920232
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000168285600125&DestApp=WOS_CPL
URL
http://repository.kulib.kyoto-u.ac.jp/dspace/handle/2433/39940
ID情報
  • DOI : 10.1109/77.920232
  • ISSN : 1051-8223
  • Web of Science ID : WOS:000168285600125

エクスポート
BibTeX RIS