論文

査読有り
2008年8月

Risk factors for nosocomial infection in the neonatal intensive care unit by the Japanese nosocomial infection surveillance (JANIS)

ACTA MEDICA OKAYAMA
  • Akira Babazono
  • Hiroyuki Kitajima
  • Shigeru Nishimaki
  • Tomohiko Nakamura
  • Seigo Shiga
  • Masahiro Hayakawa
  • Tahei Tanaka
  • Kazuo Satoh
  • Hideki Nakayama
  • Satoshi Ibara
  • Hiroshi Une
  • Hiroyuki Doi
  • 全て表示

62
4
開始ページ
261
終了ページ
268
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.18926/AMO/30938
出版者・発行元
OKAYAMA UNIV MED SCHOOL

We evaluated the infection risks in the neonatal intensive care unit (NICU) using data of NICU infection surveillance data. The subjects were 871 NICU babies, consisting of 465 boys and 406 girls, who were cared for between June 2002 and January 2003 in 7 medical institutions that employed NICU infection surveillance. Infections were defined according to the National Nosocomial Infection Surveillance (NNIS) System. Of the 58 babies with nosocomial infections, 15 had methicillin-resistant Staphylococcus aureus (MRSA) infection. Multiple logistic regression analysis demonstrated that the odds ratio for nosocomial infections was significantly related to gender, birth weight and the insertion of a central venous catheter (CVC). When the birth weight group of more than 1,500g was regarded as the reference, the odds ratio was 2.35 in the birth weight group of 1,000-1,499g and 8.82 in the birth weight group of less than 1,000g. The odds ratio of the CVC (+) for nosocomial infection was 2.27. However, other devices including artificial ventilation, umbilical artery catheter, umbilical venous catheter, and urinary catheter were not significant risk factors. The incidence of MRSA infection rapidly increased from 0.3% in the birth weight group of more than 1,500 g to 2.1% in the birth weight group of 1,000-1,499g, and to 11.1% in the birth weight group of less than 1,000g. When the birth weight group of more than 1,500g was regarded as the reference, multiple logistic regression analysis demonstrated that the odds ratio was 7.25 in the birth weight group of 1,000-1,499g and 42.88 in the birth weight group of less than 1,000g. These odds ratios were significantly higher than that in the reference group. However, the application of devices did not cause any significant differences in the odds ratio for MRSA infection.

リンク情報
DOI
https://doi.org/10.18926/AMO/30938
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000258680900006&DestApp=WOS_CPL
ID情報
  • DOI : 10.18926/AMO/30938
  • ISSN : 0386-300X
  • Web of Science ID : WOS:000258680900006

エクスポート
BibTeX RIS