Commutability of National Institute of Standards and Technology standard reference material 1955 homocysteine and folate in frozen human serum for total folate with automated assays

ANNALS OF CLINICAL BIOCHEMISTRY
  • Hiroshi Ihara
  • Toshiaki Watanabe
  • Naotaka Hashizume
  • Masayuki Totani
  • Kazuyuki Kamioka
  • Kimiko Onda
  • Satoshi Sunahara
  • Tomoko Suzuki
  • Mitsuharu Itabashi
  • Yoshikazu Aoki
  • Midori Ishibashi
  • Shozo Ito
  • Koji Ohashi
  • Tsuyoshi Enomoto
  • Kensuke Saito
  • Kayoko Saeki
  • Yoichi Nagamura
  • Tsutomu Nobori
  • Kouichi Hirota
  • Kinya Fujishiro
  • Masato Maekawa
  • Masakazu Miura
  • Yoshiji Ohta
  • 全て表示

47
6
開始ページ
541
終了ページ
548
記述言語
英語
掲載種別
DOI
10.1258/acb.2010.010094
出版者・発行元
SAGE PUBLICATIONS INC

Background: The aim of the present study was to evaluate standard reference material (SRM) 1955 commutability as a reference material for serum folate using automated methods. We also designed so as to reduce the intermethod variability present in different automated methods.
Methods: Using a microbiological assay related to the 'information value' of SRM 1955 as a comparison method, we investigated the possibility of standardization for the assay values of serum folate as measured by the automated methods (Access, Centaur and Elecsys). In the assay of 50 patient sera by these automated methods, we corrected observed values by the SRM 1955 and compared with comparison values.
Results: The observed values of SRM 1955 Levels I, II and III were within or outside (but near) a 95% prediction interval obtained from patient sera by the automated methods. The normalized residuals obtained from SRM 1955 were within +/- 3.0 (in SD units), which enabled us to conclude that the SRM 1955 had a physicochemical characterization similar to native serum. Twelve patients were assessed as hypofolataemia (<6.0 ng/mL) and 38 patients as normal (>= 6.0 ng/mL). Before correction, folate levels in six of 12 patients were lower than 6.0 ng/mL, and those in seven of 38 patients were higher than 6.0 ng/mL with the automated methods. After correction, low levels were found in four of 12 patients, and normal levels were found in 33 of 38 patients.
Conclusions: The use of SRM 1955 would help to reduce the intermethod variability present in different automated methods for serum folate measurement.

リンク情報
DOI
https://doi.org/10.1258/acb.2010.010094
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/20926465
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000285270100007&DestApp=WOS_CPL
ID情報
  • DOI : 10.1258/acb.2010.010094
  • ISSN : 0004-5632
  • eISSN : 1758-1001
  • PubMed ID : 20926465
  • Web of Science ID : WOS:000285270100007

エクスポート
BibTeX RIS