論文

査読有り
2009年6月

Shape measurement of bubble in a liquid metal

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
  • Y. Saito
  • ,
  • X. Shen
  • ,
  • K. Mishima
  • ,
  • M. Matsubayashi

605
1-2
開始ページ
192
終了ページ
196
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.nima.2009.01.168
出版者・発行元
ELSEVIER SCIENCE BV

Dynamic behavior of a two-phase bubble, i.e. a steam bubble containing a droplet evaporating in the bubble, in the molten alloy was clearly visualized using high-frame-rate neutron radiography. In relation to some direct contact heat exchanger design with molten lead-bismuth (Pb-Bi), experiments have been done at JRR-3M of JAEA (Japan Atomic Energy Agency) with water droplets evaporating in a stable thermally stratified Newton's alloy pool. The instantaneous shape and size of the bubble has been iteratively estimated from the void fraction distributions and total void volume by assuming a symmetrical bubble shape. (C) 2009 Elsevier B.V. All rights reserved.

リンク情報
DOI
https://doi.org/10.1016/j.nima.2009.01.168
CiNii Articles
http://ci.nii.ac.jp/naid/120001479078
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000268163300050&DestApp=WOS_CPL
ID情報
  • DOI : 10.1016/j.nima.2009.01.168
  • ISSN : 0168-9002
  • CiNii Articles ID : 120001479078
  • Web of Science ID : WOS:000268163300050

エクスポート
BibTeX RIS