論文

査読有り
2011年11月

High gradient test at Nextef and high-power long-term operation of devices

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
  • Shuji Matsumoto
  • ,
  • Tetsuo Abe
  • ,
  • Yasuo Higashi
  • ,
  • Toshiyasu Higo
  • ,
  • Yingchao Du

657
1
開始ページ
160
終了ページ
167
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.nima.2011.06.062
出版者・発行元
ELSEVIER SCIENCE BV

The X-band high gradient studies at Nextef, the 100 MW X-Band test station in KEK operated since 2008, is reviewed. Recent high power test results of TD18#2, an 18-cell CLIC prototype structure with HOM damping slots, are given. The measured breakdown rate is similar to 10(-5)/pulse/m under the operation at 100 MV/m gradient with 250 ns rf pulse width. The rate is higher by one- to two-order compared with that of the T18 structure, which is a disk loaded structure without the HOM slots. The recent performance of the station is also reviewed, especially that of PPM klystrons is discussed. An overview of our on-going programs such as the pulse compression system of Nextef as well as the future plans of X-band study is given. (C) 2011 Elsevier B.V. All rights reserved.

リンク情報
DOI
https://doi.org/10.1016/j.nima.2011.06.062
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000297085800026&DestApp=WOS_CPL
ID情報
  • DOI : 10.1016/j.nima.2011.06.062
  • ISSN : 0168-9002
  • eISSN : 1872-9576
  • Web of Science ID : WOS:000297085800026

エクスポート
BibTeX RIS