論文

査読有り
1999年4月1日

Data-acquisition system for a target multifragmentation experiment with large solid angle detectors

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Y. Tanaka
  • M. Haseno
  • H. Hara
  • Y. Nagasaka
  • S. Tsuji
  • K. Satake
  • K. H. Tanaka
  • J. Murata
  • R. Muramatsu
  • T. Murakami
  • Y. J. Tanaka
  • Y. Ohkuma
  • H. Ochiishi
  • F. Kosuge
  • Y. Shibata
  • R. Kubohara
  • K. Yasuda
  • Y. Sugaya
  • M. Nomachi
  • 全て表示

425
1
開始ページ
323
終了ページ
331
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/S0168-9002(98)01335-7
出版者・発行元
Elsevier Science B.V.

We have developed a CAMAC data-acquisition system that is capable of handling not only high-rate interruptions, but also over one hundred inputs within a single CAMAC crate in order to perform exclusive measurements of target multifragmentation induced by 8 and 12 GeV primary proton beams on heavy nuclei. The system is run under PC-Linux and a CAMAC auxiliary crate controller. Since we have selected the UNIDAQ data-acquisition system for our DAQ software, which only uses standard UNIX technology, we expect easy migration to another platform in a future system upgrade.

リンク情報
DOI
https://doi.org/10.1016/S0168-9002(98)01335-7
ID情報
  • DOI : 10.1016/S0168-9002(98)01335-7
  • ISSN : 0168-9002
  • SCOPUS ID : 0033115867

エクスポート
BibTeX RIS