論文

査読有り
2012年3月

Diffusion-Weighted Imaging of Breast Masses: Comparison of Diagnostic Performance Using Various Apparent Diffusion Coefficient Parameters

AMERICAN JOURNAL OF ROENTGENOLOGY
  • Maki Hirano
  • ,
  • Hiroko Satake
  • ,
  • Satoko Ishigaki
  • ,
  • Mitsuru Ikeda
  • ,
  • Hisashi Kawai
  • ,
  • Shinji Naganawa

198
3
開始ページ
717
終了ページ
722
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.2214/AJR.11.7093
出版者・発行元
AMER ROENTGEN RAY SOC

OBJECTIVE. The purpose of our study was to assess the utility of the minimum apparent diffusion coefficient (ADC), average ADC, maximum ADC, and ADC difference value and to find optimum ADC parameters for differentiation between benign and malignant lesions in breast diffusion-weighted imaging (DWI).
MATERIALS AND METHODS. Sixty-seven women with 75 masslike lesions (27 benign, 48 malignant) were examined with 3-T MRI. To assess heterogeneity within the lesion, the difference between minimum and maximum ADCs was recorded as the ADC difference value. Diagnostic performances of these parameters were compared by receiver operating characteristic (ROC) curve analysis.
RESULTS. Each ADC parameter showed significant differences between malignant and benign lesions. The optimal cutoff levels for differentiating benign versus malignant lesions were determined by identifying the points where the sensitivity and specificity were equal on the ROC curves. According to ROC analyses, the following sensitivities and specificities were obtained: average ADC, 75.6% and 75.6%; minimum ADC, 85.5% and 85.5%; maximum ADC, 63.5% and 63.5%; ADC difference value, 70.1% and 70.1%. Minimum ADC had the largest area under the ROC curve (AUC) of 0.93. Minimum ADC combined with the ADC difference value improved the AUC to 0.95, with sensitivity and specificity of 89.1% and 89.1%.
CONCLUSION. Minimum ADC may be an optimal DWI single parameter for differentiation between malignant and benign lesions of breast masses. Furthermore, the combination of the minimum ADC and ADC difference value significantly elevated diagnostic performance of breast DWI in comparison with average ADC.

リンク情報
DOI
https://doi.org/10.2214/AJR.11.7093
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/22358015
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000301069000051&DestApp=WOS_CPL
ID情報
  • DOI : 10.2214/AJR.11.7093
  • ISSN : 0361-803X
  • PubMed ID : 22358015
  • Web of Science ID : WOS:000301069000051

エクスポート
BibTeX RIS