論文

査読有り
2009年3月

Experimental Research on Element Composition of Contactless Power Station for Moving Electric Loads

J. Magn. Soc. Jpn
  • N. Nakajima
  • ,
  • F. Sato
  • ,
  • H. Matsuki

33
3
開始ページ
315
終了ページ
318
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.3379/msjmag.0903RG8046
出版者・発行元
The Magnetics Society of Japan

In this research, a contact-less power station (CLPS) is a power transmission system using a transformer that is constructed with two flat coils facing each other. It transmits power from a supply end to a receiving end without them making contact. This system is maintenance-free because there is no galling of the terminals. It is also suitable for use in harsh environments because it has no naked terminals. We developed a CLPS that is suitable for supplying energy to moving electric loads. <br>In designing the parameters, we aimed to stabilize the output voltage and improve efficiency. We also studied a suitable coil shape to supply energy to moving electric loads. Furthermore, we studied the allocation of capacitors to decrease the difference in current that was generated between each strand wire when coils were made of multiple strand wires. <br>We conducted experiments with a small-scale model that we designed with these viewpoints in mind, and met our target values.

リンク情報
DOI
https://doi.org/10.3379/msjmag.0903RG8046
CiNii Articles
http://ci.nii.ac.jp/naid/10025969993
CiNii Books
http://ci.nii.ac.jp/ncid/AA12297999
URL
http://id.ndl.go.jp/bib/10297847
URL
https://jlc.jst.go.jp/DN/JALC/00331243640?from=CiNii
ID情報
  • DOI : 10.3379/msjmag.0903RG8046
  • ISSN : 1882-2924
  • CiNii Articles ID : 10025969993
  • CiNii Books ID : AA12297999

エクスポート
BibTeX RIS