MISC

2000年

Thermophoretic mist deposition onto a tube wall cooled by liquid nitrogen

SEPARATION SCIENCE AND TECHNOLOGY
  • S Fukada
  • ,
  • Y Fujii

35
9
開始ページ
1455
終了ページ
1466
記述言語
英語
掲載種別
DOI
10.1081/SS-100100235
出版者・発行元
MARCEL DEKKER INC

Variations of the concentration of water components (vapor + mist) at the outlet of an open-column cold trap with time are determined under different gaseous streams of N-2, He, and H-2. Ice mist generated in the trap is deposited from a laminar convection flow in a vertical circular tube onto a wall surface cooled by liquid nitrogen. The mist deposition rate from the He or H-2 stream is greater than that from the N-2 Stream at the same volumetric flow rate and inlet water vapor pressure. This is because a thermophoretic force acts on mist particles more strongly in the He and H-2 streams than in the N-2 stream. The experimental mist deposition rate is compared with calculations using previous theoretical equations on thermophoresis. The open-column cold trap cooled by liquid nitrogen shows good performance to remove ice mist almost completely from gaseous streams with a comparatively small velocity.

リンク情報
DOI
https://doi.org/10.1081/SS-100100235
CiNii Articles
http://ci.nii.ac.jp/naid/80011773146
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000088483800011&DestApp=WOS_CPL
ID情報
  • DOI : 10.1081/SS-100100235
  • ISSN : 0149-6395
  • CiNii Articles ID : 80011773146
  • Web of Science ID : WOS:000088483800011

エクスポート
BibTeX RIS