Development of low-loss cryo-accelerating structure with high-purity copper

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
  • Akihiro Iino
  • ,
  • Seiya Yamaguchi
  • ,
  • Takakazu Shintomi
  • ,
  • Toshiyasu Higo
  • ,
  • Yoshisato Funahashi
  • ,
  • Shuji Matsumoto
  • ,
  • Shinichiro Michizono
  • ,
  • Kenji Ueno
  • ,
  • Katsumi Endo

866
開始ページ
40
終了ページ
47
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.nima.2017.04.012
出版者・発行元
ELSEVIER SCIENCE BV

In this paper, the development of an accelerating structure with high-purity copper operated at approximately 20 K is described. The aim is to obtain a dramatic increase in the quality factor (Q factor), which is an important parameter as regards enhancement of the acceleration gradient in a normal-conducting accelerating structure that has been operated at room temperature in the past. First, the Q factors of pillbox cavities comprised of two types of copper with different purities (99.99% and 99.99998%) were measured, at room temperature (300 K) and at a relatively low temperature (20 K); the resultant ratios, Q(0)(20 K)/Q(0)(300 K), were then compared with calculated values. Hence, it was found that the experimental and calculated values agree to within several percent, and converge to a constant value (approximately 5.3) when the residual resistance ratio is above 500. Next, a C-band accelerating structure was fabricated using a copper material having a purity of 99.99998%, and high-power testing of the structure was conducted at 20 K. Hence, it was found that the accelerating gradient E-acc reaches 30.9 MV/m with a 1.0-mu s pulse width and 50-Hz repetition rate. In the high-power test, it was revealed that the radiation dose rate for C-band structure (20 K) was about two orders of magnitude lower than that for S-band structure (303 K) under the same conditions. Further, the magnitude of the dark current generated in this structure was estimated to be several femtoamps, which was below the detection limit. This finding was based on the assumption that the dark current magnitude is proportional to the radiation dose; however, no dark current was observed. (C) 2017 Elsevier B.V. All rights reserved.

リンク情報
DOI
https://doi.org/10.1016/j.nima.2017.04.012
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000407863700007&DestApp=WOS_CPL
ID情報
  • DOI : 10.1016/j.nima.2017.04.012
  • ISSN : 0168-9002
  • eISSN : 1872-9576
  • Web of Science ID : WOS:000407863700007

エクスポート
BibTeX RIS