2019年2月21日
Measurement of the electron transmission rate of the gating foil for the TPC of the ILC experiment
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- 巻
- 918
- 号
- 開始ページ
- 41
- 終了ページ
- 53
- 記述言語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.1016/j.nima.2018.11.060
© 2018 Elsevier B.V. We have developed a gating foil for the time projection chamber envisaged as a central tracker for the international linear collider experiment. It has a structure similar to the Gas Electron Multiplier (GEM) with a higher optical aperture ratio and functions as an ion gate without gas amplification. The transmission rate for electrons was measured in a counting mode for a wide range of the voltages applied across the foil using an 55Fe source and a laser in the absence of a magnetic field. The blocking power of the foil against positive ions was estimated from the electron transmissions.