2009年3月
冬季の室内温湿度変動からみた温熱性能・環境 一般住宅とアトピー性皮膚炎患者宅の比較
日本建築学会環境系論文集
- ,
- ,
- ,
- 巻
- 74
- 号
- 637
- 開始ページ
- 305
- 終了ページ
- 314
- 記述言語
- 日本語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.3130/aije.74.305
- 出版者・発行元
- 一般社団法人日本建築学会
Heat and insulation capacities were evaluated by a regression analysis between the indoor-outdoor difference of temperature and the coefficient of variation of indoor temperature coupled with the way of living. Airtightness and ventilation were evaluated by a regression analysis between the indoor-outdoor difference of temperature and that of absolute humidity. The thermal performance in 5 houses with patients of atopic dermatitis was compared using the procedures described above. Absolute and relative humilities were extremely low in one patient house that had high-frequency ventilation.
- リンク情報
- ID情報
-
- DOI : 10.3130/aije.74.305
- ISSN : 1348-0685
- ISSN : 1881-817X
- CiNii Articles ID : 110007163887
- identifiers.cinii_nr_id : 1000080321438
- SCOPUS ID : 79954542259