MORITA Yusuke

J-GLOBAL         Last updated: Nov 13, 2018 at 19:57
 
Avatar
Name
MORITA Yusuke
Affiliation
Doshisha University
Section
Faculty of Life and Medical Sciences Department of Biomedical Engineering
Job title
Professor

Research Areas

 
 

Academic & Professional Experience

 
Apr 2007
 - 
Mar 2008
Rush University Medical Center
 

Education

 
 
 - 
2003
Graduate School, Division of Engineering, Kyoto University
 
 
 - 
1994
Graduate School, Division of Engineering, Doshisha University
 
 
 - 
1992
Faculty of Engineering, Doshisha University
 

Published Papers

 
Eiji NAKAMACHI, Kazuya MATSUMOTO, Ryota SAKIYAMA, Koji YAMAMOTO and Yusuke MORITA
Journal of Biomechanical Science and Engineering   13(2) DOI: 10.1299/jbse.18-00024   2018   [Refereed]
Development of an oxygen saturation measuring system by using near-infrared spectroscopy
K. Kono, E. Nakamachi, Y. Morita
SPIE Optical Engineering + Applications, Optics + Photonics   (10373) DOI:10.1117/12.2272395   2017   [Refereed]
Yayoi Fujimoto, Eiji Nakamachi, Yusuke Morita
Ceramics International   43,(DOI:10.1016/j.ceramint.2017.03.024) 7278-7281   2017   [Refereed]
Eiji Nakamachi, Tomohiro Noma, Kaito Nakahara, Yoshihiro Tomita, Yusuke Morita
International Journal for Numerical Methods in Biomedical Engineering   DOI: 10.1002/cnm.2864   2016   [Refereed]
Effect of epigallocatechin-3-o-gallate and quercetin on the cryopreservation of cartilage tissue
Nobuhiro Kasai, Hisashi Mera, Shigeyuki Wakitani, Yusuke Morita, Naohide Tomita & Mutsumi Takagi
Bioscience, Biotechnology, and Biochemistry   DOI: 10.1080/09168451.2016.1232156   2016   [Refereed]
T. Shimizu, M. Akahane, Y. Morita, S. Omokawaa, K. Nakano, T. Kira, T. Onishi, Y. Inagaki, A. Okuda, K. Kawate, Y. Tanaka
Injury   46(46) 1457-1464   2015   [Refereed]
Use of cryopreserved osteogenic matrix cell sheets for bone reconstruction
T. Kura, M. Akahane, T. Shimizu, Y. Uchihara, Y. Tohma, Y. Morita, M. Koizumi, K. Kawate, Y. Tanaka
Stem Cell Discovery   6(6) 13-23   2015   [Refereed]
Utility of tricalcium phosphate and osteogenic matrix cell sheet constructs for bone defect reconstruction
Tomoyuki Ueha, Manabu Akahane, Takamasa Shimizu, Yoshinobu Uchihara, Yusuke Morita, Naoya Nitta, Akira Kido, Yusuke Inagaki, Kenji Kawate, Yasuhito Tanaka
World Journal of Stem Cells   70((5)) "873-882 DOI: 10.4252/wjsc.v7.i5.873"   2015   [Refereed]
Tomohiro TAKAKI, Kazuya NAKAGAWA, Yusuke MORITA and Eiji NAKAMACHI
Mechanical Engineering Journal   Vol.2(No.3) DOI: 10.1299/mej.15-00063   2015   [Refereed]
Eiji Nakamachi, Shinya Murakami, Hirotaka Koga, and Yusuke Morita
Journal of Micro/Nanolithography, MEMS, and MOEMS   Vol. 14((2)) 025004-1-025004-10   2015   [Refereed]
Eiji Nakamachi, J. Yanagimoto, Shinya Murakami and Yusuke Morita
Journal of Micro/Nanolithography, MEMS, and MOEMS   Vol. 13(2) 023013-1-023013-9   2014   [Refereed]
Eiji Nakamachi, Takeshi Honda, Hiroyuki Kuramae, Yusuke Morita and Hideo Morimoto
International Journal of Mechanical Sciences   DOI: 10.1016(j.ijmecsci.2014.06.001)    2014   [Refereed]
Takuto Kurakawa, Kenichiro Kakutani, Yusuke Morita,Yuki Kato, Takashi Yurube, Hiroaki Hirata, Shingo Miyazaki, Yoshiki Terashima, Koichiro Maeno, Toru Takada, Minoru Doita, Masahiro Kurosaka, Nozomu Inoue, Koichi Masuda, Kotaro Nishida
The Spine Journal   (15) 417-426   2014   [Refereed]
Eiji Nakamachi,Takeshi Honda, Hiroyuki Kuramae ,Yusuke Morita,Tomiso Ohata, HideoMorimoto
International Journal of Mechanical Sciences   (80) 109-121   2013   [Refereed]
Multi-scale finite element analyses for stress and strain evaluations of braid fibril artificial blood vessel and smooth muscle cell
Eiji Nakamachi, Takahiro Uchida, Hiroyuki Kuramae and Yusuke Morita
International Journal for Numerical Methods in Biomedical Engineering   DOI: 10.1002/cnm.2630   2013   [Refereed]
Y Morita, H. Kondo, N. Tomita, S. Suzuki
J Orthop Sci.   17(3) 272-280   2012   [Refereed]
Nakamachi, E., Mizuno, Y. and Morita Y.
Int. J. of Optics   Vol. 2012, Article ID 258626 11pages   2012   [Refereed]
Nakamachi, E., Hwang, H., Okamoto, N. and Morita, Y.
J. Micro/Nanolith. MEMS MOEMS   10(3) pp. 033013-1-7   2011   [Refereed]
Akifumi Nakamura, Manabu Akahane, Hideki Shigematsu, Mika Tadokoro, Yusuke Morita, Hajime Ohgushi, Yoshiko Dohi, Tomoaki Imamura, Yasuhito Tanaka
Bone   Vol. 46 418-424   2010   [Refereed]
Yusuke Morita, Kenichi Yamasaki, Koji Hattori
Clinical Biomechanics   Vol. 25 829-834   2010   [Refereed]
Yusuke Morita, Naohide Tomita, Hideyuki Aoki, Masato Sonobe, Shigeyuki Wakitani, Yasushi Tamada, Toru Suguro, and Ken Ikeuchi
Journal of Biomechanics   39 103-109   2006   [Refereed]
Proc. IMechE. Part H: J. Engineering in Medicine   219 175-182   2005   [Refereed]
Hattori K, Takakura Y, Morita Y, Takenaka M, Uematsu K, Ikeuchi K
Rheumatology (Oxford)   43(3) 302-305   2004   [Refereed]
Wear properties of alumina/zirconia composite ceramics for joint prostheses measured with an end-face apparatus
Yusuke Morita, Kenichi Nakata, Yoon-Ho Kim, Tohru Sekino, Koichi Niihara, and Ken Ikeuchi
Bio-medical materials and engineering   14(3) 263-270   2004   [Refereed]
Embryonic stem cells form articular cartilage,not teratomas,in osteochondral defects of rat joints
Shigeyuki Wakitani, Hideyuki Aoki, Yasuji Harada, Masato Sonobe, Yusuke Morita, Ying Mu, Naohide Tomita, Yukio Nakamura, Satoshi Takeda, Takeshi K. Watanabe, and Akira Tanigami
Cell Transplantation   13 331-336   2004   [Refereed]
Quantitative ultrasonic assessment for detecting microscopic cartilage damage in osteoarthritis
Koji Hattori, Ken Ikeuchi, Yusuke Morita, Yoshinori Takakura
Arthritis Research & Therapy   7(1) 38-46   2004   [Refereed]
Yusuke Morita, Kenichi Nakata, Ken Ikeuchi
Wear   254(1+2) 147-153   2003   [Refereed]
Culture of chondorocytes in fibroin-hydrogel sponge
Hideyuki Aoki, Naohide Tomita, Yusuke Morita, Koji Hattori, Yasuji Harada, Masato Sonobe, Shigeyuki Wakitani, Yasushi Tamada
Bio-medical materials and engineering   13(4) 309-316   2003   [Refereed]
Evaluation of dynamic visco-elastic properties during cartilage regenerating process in vitro
Yusuke Morita, Naohide Tomita, Hideyuki Aoki, Shigeyuki Wakitani, Yasushi Tamada, Toru Suguro, and Ken Ikeuchi
Bio-medical materials and engineering   13(4) 345-353   2003   [Refereed]
Visco-elastic properties of cartilage tissue regenerated with fibroin sponge
Yusuke Morita, Naohide Tomita, Hideyuki Aoki, Shigeyuki Wakitani, Yasushi Tamada, Toru Suguro, and Ken Ikeuchi
Bio-medical materials and engineering   12 291-298   2002   [Refereed]
Effect of tribochemical reaction on wear of silicon carbide for joint prostheses
K. Ikeuchi, Y. Morita, H. Yoshida, J. Kusaka
Journal of ceramic processing research   2(1) 35-37   2001   [Refereed]
Fatigue degradation and life prediction of glass fabric polymer composite under tension/torsion biaxial loadings
Kawakami Hiroshi, Fujii Toru, Morita Yusuke
Journal of Reinforced Plastics and Composites   15(2) 183-195   1996   [Refereed]

Misc

 
Development of Three-dimensional Forearm Vein Imaging System Using Light-section Method for Automatic Blood Sampling
Eiji NAKAMACHI, Masaki NAKAGAWA, Ryouhei KIMURA, Yusuke MORITA
58巻(1号) 11-18   2017   [Refereed]
Development and Evaluation of Double-Frequency Vibration Energy Harvester Using Multi-Morph Piezoelectric Cantilever
Eiji NAKAMACHI, Yuji GOTO, Yusuke MORITA
58巻(1号) 1-10   2017   [Refereed]
Eiji NAKAMACHI, Masaki NAKAGAWA, Kazuyuki NARITA, Yusuke MORITA, Akeo HAGIWARA
56巻(4号) 232-244   2016   [Refereed]
DEVELOPMENT OF IKVAV MODIFIED PLLA GUIDE TUBE HAVING UNIDIRECTIONAL FIBERS ON INNER SURFACE TO ENHANCE AXONAL EXTENSION
Yasuo Akizawa,Yusuke Morita,Yu-I Hsu,Tetsuji Yamaoka,Eiji Nakamachi
Proc. of ASME 2016 International Mechanical Engineering Congress & Exposition   CD-ROM IMECE2016-66458.   2016   [Refereed]
DEVELOPMENT OF HYBRID ELECTROMAGNETIC AND MECHANICAL STIMULATION SYSTEM FOR ENHANCEMENT OF NERVE AXONAL EXTENSION
Kazuya Matsumoto,Eiji Nakamachi,Yusuke Morita
Proc. of ASME 2016 International Mechanical Engineering Congress & Exposition   CD-ROM IMECE2016-65593.   2016   [Refereed]
STRESS EVALUATION OF ARTICULAR CARTILAGE CHONDROCYTE CELL BY USING MULTI-SCALE FINITE ELEMENT METHOD AND SMOOTHED PARTICLE HYDRODYNAMICS METHOD
Kaito Nakahara,Eiji Nakamachi,Yusuke Morita,Yoshihiro Tomiya
Proc. of ASME 2016 International Mechanical Engineering Congress & Exposition   CD-ROM IMECE2016-66416.   2016   [Refereed]
TWO-SCALE THERMO-CRYSTAL PLASTICITY FINITE ELEMENT ANALYSIS OF DYNAMIC-RECRYSTALLIZATION TEXTURE EVOLUTION
Yuhei Ueda, Yu Goto, Toshihiko Yamaguchi, Yoshihiro Tomita, Yusuke Morita, Eiji Nakamachi
Proc. of ASME 2016 International Mechanical Engineering Congress & Exposition   CD-ROM IMECE2016-66437.   2016   [Refereed]
EFFECT OF THE GRADIENT MAGNETIC FIELD STIMULATION ON EXTRACELLULAR MATRIX SYNTHESIS OF CHONDROCYTE
Tomoko Saito,Yusuke Morita,Eiji Nakamachi
Proc. of ASME 2016 International Mechanical Engineering Congress & Exposition   CD-ROM IMECE2016-66419.   2016   [Refereed]
DEVELOPMENT OF SURFACE TREATMENT TECHNIQUE WITH PHOTOLYTIC MACROMOLECULE INCLUDING RGDS PEPTIDE
Yukiko Taki,Yusuke Morita,Eiji Nakamachi,Shinnosuke Nishimura,Ayaha Hirai
Proc. of ASME 2016 International Mechanical Engineering Congress & Exposition   CD-ROM IMECE2016-66466.   2016   [Refereed]
DEVELOPMENT OF MULTI-LAYERED CELLULAR AUTOMATA MODEL TO PREDICT NERVE AXONAL EXTENSION PROCESS
A. NAKAYAMA, T. YAMAMOTO, Y. MORITA AND E. NAKAMACHI
VI International Conference on Computational Bioengineering ICCB 2015   1-9   2015   [Refereed]
Laparoscopic Optical Sensing of Gastroepiploic Artery Using Near-infrared Light Stereo Method
E. NAKAMACHI, Y. MORITA AND H. SAKAMOTO
2015 Ninth International Conference on Sensing Technology   doi: 978-1-4799-6314-0/15 568-571   2015   [Refereed]
E. Nakamachi, T. Yoshida, H. Kuramae, H. Morimoto, T. Yamaguchi, Y. Morita
Proc. of ICCMSE 2014: AIP Conference Procceedings   1618: DOI: 10.1063/1.4897739 323-326   2014   [Refereed]
T. Yamaguchi, K. Ohyabu, H. Kuramae, H. Morimoto, Y. Morita, E. Nakamachi
Proc. of ICCMSE 2014: AIP Conference Procceedings   1618: DOI: 10.1063/1.4897738 319-322   2014   [Refereed]
H. Kuramae, T. Honda, H. Morimoto, Y. Morita, E. Nakamachi
Proc. of ICCMSE 2014: AIP Conference Procceedings   1618: DOI: 10.1063/1.4897736 311-314   2014   [Refereed]
Evaluation of electrical impedance related to matrix composition of articular cartilage using the two-electrodes impedance measurement
A. Takai, Y. Morita, E. Nakamachi
Proc. of 2013 BMES Annual Meeting   140-3   2013
Effects of surface gel layer on adsorption of proteins and frictional properties of articular cartilage
A. Takai, Y. Morita, E. Nakamachi
Proc. of 2013 BMES Annual Meeting   140-4   2013
Evaluation of electrical impedance related to matrix composition of articular cartilage using the two-electrodes impedance measurement
Y. Sato, Y. Morita, E. Nakamachi
Proc. of 2013 BMES Annual Meeting   140-3   2013
Evaluation of Chondrocyte Damage under Impact Hydrostatic Pressure
T. Yamaguchi, Y. Morita, E. Nakamachi
Proc. of 2013 BMES Annual Meeting   140-2   2013
Quantitative evaluation of cell adhesion toward RAD16RGDS peptide coated substrate
Y. Tagawa, Y. Morita, Y. Hirano, E. Nakamachi
Proc. of 2013 BMES Annual Meeting   140-1   2013
Optimum design of magnetic field environment for axonal growth control in nerve cell regeneration process using electromagnetic field analyses
Proc. of COMPLAS XII, (2013-9)(CDROM)   p.513   2013
BioMed Research International   Volume 2013 Article ID 842192   2013
"Bending and Springback Prediction Method Based on Multi-scale Finite Element Analyses for High Bendability and Low Springback Sheet Generation "
T. Honda, H.i Kuramae, H. Morimoto, Y. Morita, T. Ohata, E. Nakamachi
Proc. of Computational Plasticity Xll   CD-ROM 184-195.   2013   [Refereed]
Cristal Design and Generation of a New Biocompatible Piezoelectric Mixed Crystal - Ti Doped MgSiO3 -Thin Film, Proc. of 35th Annual
K. Nose, E. Nakamachi, Y. Uetsuji,
Proc. of International Conference of the IEEE Engineering in Medicine and Biology Society   CD-ROM 112   2013   [Refereed]
K.Narita, E.Nakamachi, Y. Morita, A. Hagiwara,
Proc. of SPIE 2013 Optics+Photonics   Vol. 8839 1-10.   2013   [Refereed]
K. Cheng, K. Narita, Y. Morita, E. Nakamachi,
Proc. of SPIE 2013 Optics+Photonics   Vol. 8841    2013   [Refereed]
Crystal Texture Evolution Analyses in Metal Drawing Processes by Using Two-scale Finite Element Method
T. Yoshida, H. Kuramae, H. Morimoto, T. Yamaguchi, T. Ohata, E. Nakamachi,
Proc. of Computational Plasticity Xll   CD-ROM 1427-1435.   2013   [Refereed]
Process Metallurgy Analyses of Sheet Rolling by Thermal Elastic Plastic Multi-Scale Finite Element Method
K. Ohyabu, T. Honda, H. Kuramae, H. Sakamoto, Y. Morita, E. Nakamachi
Proc. of Computational Plasticity Xll   CD-ROM a549.   2013   [Refereed]
2D Phase-Field Analyses of Axonal Extension of Nerve Cell
K. Nakagawa, T. Takaki, Y. Morita, and E. Nakamachi
Proc. of ASME IMECE 2013, (2013-11)   CD-ROM IMECE2013-64281   2013   [Refereed]
K. Fukatani, R. Mizuta, Y. Morita, H. Sakamoto, and E. Nakamachi
Proc. of ASME 2013 International Mechanical Engineering Congress & Exposition   CD-ROM IMECE2013-64289.   2013   [Refereed]
S. MURAKAMI,Y. MORITA, and E. NAKAMACHI
Proc. of ASME 2013 International Mechanical Engineering Congress & Exposition   CD-ROM IMECE2013-64284.   2013   [Refereed]
High Resolution MR Image Based Finite Element Analyses of Meniscus in Human Knee Joint
Proc. WCCM2012(CD-ROM)      2012   [Refereed]
Development of micro-pump for bio-MEMS by using new bio-compatible piezoelectric material MgSiO3
Proc. of SPIE Smart Structures and Material + Nondestructive Evaluation and Health Monitoring   7981-182   2011   [Refereed]
Proc. of 2011 Smart Nano+Micro Materials and Devices(CD-ROM)      2011   [Refereed]
Development of portable health monitoring system device for automatic self-blood sugar level measurement
Proc. of SPIE Photonics West Conf.   7556(34)    2010   [Refereed]
Effect of Alternating Magnetic Fied at Extremely Low Frequency on Cells: Secretion of Insulin by Beta Cells
Proceedings of The 2nd International Conference on Cybernetics and Information Technologies, Systems and Applications   1 281-285   2005
Measurement of Mechatronic Property of Biological Gel with Micro-Vibrating Electrode
Proceedings of The 2nd International Conference on Cybernetics and Information Technologies, Systems and Applications   1 276-280   2005
Development of Radio Frequency Pick-up Archimedean Spiral Coil for Magnetic Resonace Image
Proceedings of The 2nd International Conference on Cybernetics and Information Technologies, Systems and Applications   1 103-106   2005
Wear process under concentrated contact in alumina/alumina hip joint
Life Cycle Tribology (Proceedings of the 31st Leeds-Lyon Symposium on Tribology)   179–184   2005   [Refereed]
A novel technique for evaluation of articular cartilage lubrication based on the surface plasmon resonance
Life Cycle Tribology (Proceedings of the 31st Leeds-Lyon Symposium on Tribology)   389–397   2005   [Refereed]
Evaluation of Property of Articular Cartilage with Electric Impedance
Proceedings of The 2nd International Conference on Cybernetics and Information Technologies, Systems and Applications   1 286-289   2005
Effect of Surface Morphology of Ceramic Implant on Adhesion to Bone Plate with Bone Marrow Derived Mesenchymal Stem Cell
Proceedings of The 2nd International Conference on Cybernetics and Information Technologies, Systems and Applications   2 121-125   2005
Effect of aging on deformability of erythrocytes in shear flow
Proceedings of the 8th world multi-conference on systemics, cybernetics and informatics   215-219   2004
Measurement system for mechatronic property of biological electrolyte solution with micro-vibrating electrode
Proceedings of the 8th world multi-conference on systemics, cybernetics and informatics   199-203   2004
Effect of magnetic field on cells
Proceedings of the 8th world multi-conference on systemics, cybernetics and informatics   177-182   2004
Measurement system for body temperature during transition period of hibernating animal
Proceedings of the 8th world multi-conference on systemics, cybernetics and informatics   156-159   2004
Quantitative evaluation of adhesion between ceramic implant and bone plate with bone marrow derived mesenchymal stem cell
Proceedings of the 8th world multi-conference on systemics, cybernetics and informatics   220-223   2004
Effect of magnetic field at low frequency on cells arrangement
Proceedings of the 7th World Multiconference on Systemics, cybernetics and Information   62-66   2003
Simulation of cell group formation regulated by coordination number, cell cycle and duplication frequency
Proceedings of The 7th World Multiconference on Systemics, cybernetics and Information   26-31   2003
Biological lubrication of hydrated surface layer in small intestine
Tribological research and design for engineering systems (Proceeding 29 Leeds-Lyon Symposium on Tribology, 2002), D. Dowson et al. ed.   425-428   2003   [Refereed]
Wear Mechanism between Alumina and Zirconia Ceramics for Ceramic/Ceramic Total Hip Prostheses
Proceeding of the 4th ISEPD   5-8   2003
Effects of watercontents of poly (vinyl alchol) hydrogel as artificial articular cartilage on damage degree of natural articular cartilage
Proceedings of the 4th International Biotribology Forum and the 24th Biotribology Symposium   14-17   2003
Frictional properties of regenerated cartilage in vitro
Proceedings of the 4th International Biotribology Forum and the 24th Biotribology Symposium   22-24   2003
Wear test simulating concentrated contact during relocation after microseparation in all-ceramic hip joint
Proceedings of the 4th International Biotribology Forum and the 24th Biotribology Symposium   46-48   2003
Aqueous lubrication with hydrated macromolecules attaching to tissue surface
Proceedings of the 4th International Biotribology Forum and the 24th Biotribology Symposium   72-73   2003
Study of the influence of the superficial conditions of articular cartilage during lubrication
Proceedings of the 4th International Biotribology Forum and the 24th Biotribology Symposium   74-76   2003
Wear of alumina/zirconia nano-composite for ceramic/ceramic joint prostheses
K.Ikeuchi, Y.Morita, K.Nakata, Y.H.Kim, T.Sekino, K.Niihara
Tribological Research and Design for Engineering Systems   257-261   2003   [Refereed]
Effect of magnetic field at low frequency on cells
IFMBE Proceedings   1402-1403   2002
Application of quartz crystal oscillator to atmospheric molecule sensor
IFMBE Proceedings   304-305   2002
Measurement of the mechanical properties of the regenerated articular cartilage using wavelet transfo rmation
Tissue Engineering for Therapeutic Use 6, Yoshio Ikada ed., elsevier   133-142   2002   [Refereed]
Effect of sliding direction on wear properties of ceramics for joint prostheses
Tribology in Biomechanical Systems: science and applications, F. Franek/A. Pauschitz/K. Judmann, eds., expert verlag   128-135   2001   [Refereed]
Effect of dissolved oxygen on wear of silicon carbide for joint prostheses
Tribology in Biomechanical Systems: science and applications, F. Franek/A. Pauschitz/K. Judmann, eds., expert verlag   136-142   2001   [Refereed]
Fatigue degradation and life estimation of polymer matrix composites subjected to tension//torsion biaxial loads having different loading sequences and paths
Composites'95; Recent advances in Japan and the United states, Isao Kimpara/Hiroo Miyairi/Nobuo Takeda eds.   585-592   1995   [Refereed]
Effects of Shear Stress Component and Loading Path on Fatigue Strength under Tension/Torsion Biaxial Cyclic Loading
PROCEEDINGS OF THE AMERICAN SOCIETY FOR COMPOSITES (NINTH TECHNICAL CONFERENCE)   975-982   1994   [Refereed]

Conference Activities & Talks

 
Effect of sliding direction on wear properties of ceramics for joint prostheses
1st Vienna Symposium on Biomechanical Engineering (2nd World Tribology Congress)   2001   
Effect of dissolved oxygen on wear of silicon carbide for joint prostheses
1st Vienna Symposium on Biomechanical Engineering (2nd World Tribology Congress)   2001   
Visco-elastic properties of regenerated cartilage tissue using fibroin sponge
Switzerland-Japan Worlshop on “ New directions in cellular and tissue biomechanics”   2001   
A new scaffold for articular cartilage regeneration of fibroin sponge
ISTA 2001: The 14th annual symposium of the international society for technology in arthroplasty   2001   
Reconstruction of knee joint using total knee regeneration system
The sixth International Symposium on Tissue Engineering for Therapeutic Use (TETU-6)   2001   
Measurement of the mechnical properties of the regenerated articular cartilage using wavelet transformation
The sixth International Symposium on Tissue Engineering for Therapeutic Use (TETU-6)   2001   
Mechanical function of regenerated cartilage tissue formed in fibroin-hydrogel sponge
Orthopaedic research society 48th annual meeting   2002   
Mechanical function of cartilage tissue regenerated using fibroin-hydrogel sponge
SICOT/SIROT 2002 ⅩⅩⅡ World congress   2002   
Biological lubrication of hydrated surface layer in small intestine
29th Leeds-lyon symposium on tribology   2002   
Wear of alumina/zirconia nano-composite for ceramic/ceramic joint prostheses
29th Leeds-lyon symposium on tribology   2002   
Wear properties of alumina/zirconia nano-composite ceramics for all ceramic joint prostheses
CUP between Japan and Korea Osaka seminar   2002   
ES cells transplanted into the rat knee joint form a hyaline cartilage structure
Orthopaedic research society 49th annual meeting   2003   
Lubrication of articular cartilage by surface layer of hydrated molecules
ICBN 2003   2003   
The role of hydrated surface layer in joint lubrication
International Nanotribology Forum   2003   
Evaluation of microscopic damage to articular cartilage using ultrasonic probe
SICOT/SIROT 2003 International Conference in Cairo   2003   
Embryonic Stem Cells Transplanted into Osteochondral Defect in the Rat Knee Joint Form a Hyaline Cartilage Structure
International Society for Technology in Arthroplasty(ISTA) 2003   2003   
Wear process under concentrated contact in alumima /alumina hip joint
31st Leeds-Lyon Symposium on Tribology   2004   
A novel technique for evaluation of articular cartilage lubrication based on the surface plasmon resonance
31st Leeds-Lyon Symposium on Tribology   2004   
Effect of Surface Morphology of Ceramic Implant on Adhesion to Bone Plate with Bone Marrow Derived Mesenchymal Stem Cell
The 2nd International Conference on Cybernetics and Information Technologies, Systems and Applications   2005   
Evaluation of property of articular cartilage with electric impedance
Proc. of the 2nd International Conference on Cybernetics and Information Technologies, Systems and Applications   2005   
Measurment of Fixation between Ceramic Implant and Bone: Evaluation with Bone Marrow Derived Mesenchymal Stem Cell In Vitro
19th European Conference on Biomaterials   2005   
Mechatronic Property of Biological Gel: Mesurement with Micro-Vibrating Electrode
19th European Conference on Biomaterials   2005   
Effect of hydroxyapatite on adhesion strength of artificial joint
20th European Conference on Biomaterials   2006   
Evaluation of mechanical property of articular cartilage using electric impedance method: Measurement with two-electrode method
21th European Conference on Biomaterials   2007   
In vitro evaluation of cell activity and implant fixation for titanium alloy plate with various surface treatment
21th European Conference on Biomaterials   2007   
Effects of In Vitro Injections of Osteogenic Protein-1 on the Viscoelastic Properties of the Intervertebral Disc under Conditions of Limited Nutrient
54th Annual Meeting of the Orthopaedic Research Society   2008   
A new therapeutic strategy for facet cartilage degeneration: interleukin-1 receptor antagonist and soluble tumor necrosis factor receptor upregulate the extra cellular matrix metabolism of human facet joint articular chondrocytes
54th Annual Meeting of the Orthopaedic Research Society   2008   
Cytokine Inhibitors Stimulated Proteoglycan Anabolism and Inhibited Proteoglycan Catabolism of Human Facet Joint Articular Chondrocytes
Spineweek 2008   2008   
Intradiscal Injection of Osteogenic Protein-1 Modulated the Viscoelastic Properties of Intervertebral Discs Cultured In Vitro with Limited Nutrient Transport
Spineweek 2008   2008   
Evaluation of mechanical property of articular cartilage using the two-electrode electric impedance method
22nd European Conference on Biomaterials   2009   
Development of Dynamic Multi-Scale Finite Element Analysis Code for Brain Injury Prediction
Proc. of 9th World Cong. On Comp. Mech. (WCCM) conference   2010   
Micro Finite Element Analysis of Trabecular Bone Tissue by Using μ-CT Measured RVE Model
Proc. of 9th World Cong. On Comp. Mech. (WCCM) conference   2010   
Evaluation of compressive stiffness of enzyme-treated cartilage using electric impedance method
23nd European Conference on Biomaterials   2010   
Effect of pulse electric field stimulation on the activity of chondrocytes
23nd European Conference on Biomaterials   2010   
Acceleration of osteogenesis by using barium titanate piezoelectric ceramic as an implant material
2011   
Evaluation of compressive stiffness of articular cartilage using a two-electrode electric impedance method
24th European Conference on Biomaterials   2011   
Lubrication mechanism of hydrogel layer on articular cartilage surface
24th European Conference on Biomaterials   2011   
Effect of pulse electric field stimulation on mechanical property of cultured cartilage
24th European Conference on Biomaterials   2011   
Development of Electric Power Generation System for Bio-MEMS Device by Using A New Bio-compatible Piezoelectric Material MgSiO3
2011 Smart Nano+ Micro Materials and Devices   2011   
The Effect of Osteogenic Matrix Sheet on Tendon Graft to Bone Tunnel Healing in Rabbits
ORS 2012   2012   
Biologic Response of Rat Intervertebral Disc to Dynamic Compression -Analysis of Mechanoreceptors in Dynamic Organ Culture System
ORS 2012   2012   
Biologic responses of rat intervertebral discs to mechanical loading using a dynamic organ culture system
SpineWeek 2012   2012   
Bendability Evaluation of Copper Alloy Sheet Metal by Multi-scale Finite Element Analyses
10th WORLD CONGRESS ON COMPUTATIONAL MECHANICS   2012   
High Resolution MR Image Based Finite Element Analyses of Meniscus in Human Knee Joint
10th World Congress on Computational Mechanics   2012   
Development of Magnetic Induced Vibration Energy Harvester for Low-frequency
34th Annual International Conference of the IEEE Engneering in Medicine & Biology Society   2012   
Multi-scale and multi-physics finite element analyses of articular cartilage and chondrocyte
6th EUROPEAN CONGRESS ON COMPUTATIONAL METHODS IN APPLIED SCIENCES AND ENGINEERING (ECCOMAS 2012)   2012   
Multi-scale Finite Element Analyses and Syntheses of 3D Scaffold for Blood vessel Tissue Regeneration
6th European Congress on Computational Methods in Applied Sciences and Engineering   2012   
2D Phase-Field Analyses of Dendrite and Axon Growth of Nerve Cell
6th European Congress on Computational Methods in Applied Sciences and Engineering   2012