論文

査読有り
2018年2月8日

Winding orientation method to minimise the secondary leakage of a gapped transformer utilised in LLC resonant converter

Electronics Letters
  • M. Noah
  • ,
  • K. Umetani
  • ,
  • M. Yamamoto
  • ,
  • J. Imaoka

54
3
開始ページ
157
終了ページ
159
記述言語
掲載種別
研究論文(学術雑誌)
DOI
10.1049/el.2017.4013

It is a common practice in the LLC resonant converter to utilise the transformer leakage inductance as an inductive component in the resonant tank. Nonetheless, the leakage does not exist only on the primary side but also on the secondary side. This Letter proposes a winding orientation method to minimise the undesirable secondary leakage in the transformer. The basic theory of the proposed method relies on Dowell's model and Ampere's law to minimise the stored magnetic energy originated from the secondary windings. Along with the theoretical analysis, experimental tests have been conducted to evaluate the proposed method. The measurements of the leakage inductance are consistent with the expectations of the proposed winding orientation method.

リンク情報
DOI
https://doi.org/10.1049/el.2017.4013
Scopus
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85041643350&origin=inward
Scopus Citedby
https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85041643350&origin=inward
ID情報
  • DOI : 10.1049/el.2017.4013
  • ISSN : 0013-5194
  • SCOPUS ID : 85041643350

エクスポート
BibTeX RIS