MISC

本文へのリンクあり
2015年

Attempt to generate a strong and uniform magnetic field by face-to-face HTS bulk elements in a magnet system

Physics Procedia
  • Tetsuo Oka
  • ,
  • Eri Hirayama
  • ,
  • Yasuhiro Takahashi
  • ,
  • Tomoaki Kanai
  • ,
  • Jun Ogawa
  • ,
  • Satoshi Fukui
  • ,
  • Takao Sato
  • ,
  • Kazuya Yokoyama
  • ,
  • Takashi Nakamura

67
開始ページ
1005
終了ページ
1009
DOI
10.1016/j.phpro.2015.06.187

© 2015 The Authors. A unique experimental attempt aiming to obtain a uniform magnetic field space as required for NMR has been carried out with use of HTS bulk magnets. The magnetic poles were activated as 1.8 T (North) and 1.4 T (South) at 30 K by applyinga pulsed magnetic field up to 7 T, and positioned face-to-face with gaps less than 70 mm. The uniformity of the magnetic field required for detecting the NMR signals isless than 1,500 ppm at more than 0.3 T in the cross sectional plane of 2 x 2 mm2. After thepreliminary trials whichrevealed auniformity of 5,421 ppm at 0.44 T in a70 mm gap, we attached a ferromagnetic iron plate to a magnetic pole surface to change the magnetic field distribution to be concave. The best uniformity of 358 ppm at 1.11 T was obtained at 9 mm distance from the iron plate surface in a gap of 30 mm. It is stated that the concave magnetic field distribution was compensated by the counter conical-shape field, resulting in the uniform field plane.

リンク情報
DOI
https://doi.org/10.1016/j.phpro.2015.06.187
Scopus
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84948424037&origin=inward 本文へのリンクあり
Scopus Citedby
https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=84948424037&origin=inward
ID情報
  • DOI : 10.1016/j.phpro.2015.06.187
  • ISSN : 1875-3884
  • eISSN : 1875-3892
  • SCOPUS ID : 84948424037

エクスポート
BibTeX RIS