論文

査読有り
2013年

New polymer gel dosimeters consisting of less toxic monomers with radiation-crosslinked gel matrix

7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE)
  • A. Hiroki
  • ,
  • S. Yamashita
  • ,
  • Y. Sato
  • ,
  • N. Nagasawa
  • ,
  • M. Taguchi

444
1
開始ページ
012028
終了ページ
記述言語
英語
掲載種別
研究論文(国際会議プロシーディングス)
DOI
10.1088/1742-6596/444/1/012028
出版者・発行元
IOP PUBLISHING LTD

New polymer gel dosimeters consisting of less toxic methacrylate-type monomers such as 2-hydroxymethyl methacrylate (HEMA) and polyethylene glycol 400 dimethacrylate (9G) with hydroxypropyl cellulose (HPC) gel were prepared. The HPC gels were obtained by using a radiation-induced crosslinking technique to be applied in a matrix instead of a gelatin, which is conventionally used in earlier dosimeters, for the polymer gel dosimeters. The prepared polymer gel dosimeters showed cloudiness by exposing to Co-60 gamma-ray, in which the cloudiness increased with the dose up to 10 Gy. At the same dose, the increase in the cloudiness appeared with increasing concentration of 9G. As a result of the absorbance measurement, it was found that the dose response depended on the composition ratio between HEMA and 9G.