J0540101 電気穿孔および等速電気泳動を用いた一細胞cytoplasmic RNA抽出法における純度計測

年次大会 : Mechanical Engineering Congress, Japan
  • 畑 翔太
  • ,
  • 横川 隆司
  • ,
  • 小寺 秀俊
  • ,
  • 新宅 博文

2015
開始ページ
"J0540101
終了ページ
1"-"J0540101-3"
記述言語
日本語
掲載種別
出版者・発行元
一般社団法人日本機械学会

We report on our efforts to measure the purity of RNA extracted from single cells via electrical lysis and ITP (isotachophoresis). We have developed a fluorescence microscopy to quantify absolute masses of RNA and protein focused at ITP interface with fluorescence dyes that specifically bind with RNA and protein, respectively. This quantification is performed without enzymatic amplification in less than 5 min. We demonstrate our technique using K562 single cells, for which we obtained an average of 12.1±1.6 pg and 43.8±8.8 pg of RNA and protein masses, respectively, and 36.3±4.9% of RNA purity.